Key result
A hybrid ablation approach combining an endocardial cryoballoon and epicardial bipolar radiofrequency achieved acute bidirectional block in 7/7 patients with no complications.
Why the study?
Does a hybrid approach combining endocardial cryoballoon and epicardial bipolar RF ablation provide a feasible and safe treatment for atrial fibrillation in patients with severe COPD?
Cohort (n=7)
Does a hybrid approach combining endocardial cryoballoon and epicardial bipolar RF ablation provide a feasible and safe treatment for atrial fibrillation in patients with severe COPD?
A hybrid ablation approach combining epicardial bipolar RF and endocardial cryoballoon is feasible and safe for treating AF in patients with severe COPD who cannot tolerate bilateral sequential lung deflation.
OBJECTIVES: Bipolar radiofrequency (RF) devices are used epicardially by cardiac surgeons and cryoballoon endocardially by cardiac electrophysiologists for atrial fibrillation (AF) ablation, but in separate entities. The study's objective was to evaluate the feasibility and safety of combining an endocardial cryoballoon with epicardial bipolar RF ablation for the treatment of AF. METHODS: A cohort of 7 patients with AF underwent a hybrid thoracoscopic surgical and endocardial ablation. To prevent bilateral sequential lung deflation in these patients with severe chronic obstructive pulmonary disease, the right pulmonary veins (PVs) were isolated using an epicardial bipolar RF clamp and the contralateral veins with an endocardial cryoballoon. A box lesion set was made epicardially using a bipolar RF pen. RESULTS: Acutely, pacing manoeuvres proved a bidirectional block in all PVs in all patients. No complications were seen. A box lesion was made in 5 patients. During follow-up, 2 of them had AF recurrence: 1 was treated successfully with sotalol and another underwent redo RF catheter ablation with reisolation of the right inferior PV. At present, 6 of 7 patients are in sinus rhythm without any anti-arrythmic drugs during a follow-up of more than 40 ± 3 months. CONCLUSIONS: A hybrid approach to AF ablation using a cryoballoon endocardially and a bipolar RF device epicardially is feasible and safe.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2014) conducted a cohort in Atrial fibrillation (n=7). Hybrid approach combining endocardial cryoballoon and epicardial bipolar radiofrequency ablation was evaluated on Feasibility and safety (acute bidirectional block and complications). A hybrid ablation approach combining an endocardial cryoballoon and epicardial bipolar radiofrequency achieved acute bidirectional block in 7/7 patients with no complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: