Key result
St. Jude prosthetic valves exhibited higher peak mitral flow velocities compared to native valves but similar pressure half-times.
Why the study?
Does Doppler echocardiography accurately define the flow characteristics of St. Jude Medical prosthetic valves compared to native valves?
Observational (n=23)
Does Doppler echocardiography accurately define the flow characteristics of St. Jude Medical prosthetic valves compared to native valves?
Answers are grounded in this paper and cite their sources.
Doppler echocardiography provides quantitative transprosthetic flow characteristics for St. Jude valves and can identify prosthetic dysfunction such as paravalvular leaks.
To determine whether the flow characteristics of aortic and mitral St. Jude Medical valves could be defined noninvasively, we analyzed Doppler transprosthetic flow velocity spectra in 23 relatively asymptomatic patients. Results were interpreted in the framework of M mode and two-dimensional echocardiographic data and were compared with Doppler transvalvular flow velocity spectra from native valves of healthy subjects. Although the morphologic characteristics of Doppler spectra were similar, peak and mean transprosthetic mitral flow velocities were higher than values obtained across native valves (1.38 +/- 0.3 m/sec and 0.73 +/- 0.1 m/sec vs 0.78 +/- 0.1 m/sec and 0.35 +/- 0.06 m/sec, respectively; p less than .001). However, calculated pressure half-times were not different (61.2 +/- 16.9 msec vs 57.2 +/- 13.2 msec; p greater than .05) and calculated transprosthetic mitral gradients were small (2.3 +/- 0.9 mm Hg). Similarly, the morphologic characteristics of aortic Doppler flow spectra in St. Jude and native valves were analogous. However, prosthetic valves exhibited higher peak and mean velocities (p less than .01) and slightly prolonged time-to-peak flow (p = .02). M mode and two-dimensional studies did not show useful quantitative measures of prosthetic function and did not demonstrate evidence of paravalvular leaks, which were detected in four cases by Doppler techniques. Thus Doppler echocardiography provides quantitative information about transprosthetic flow characteristics in patients with implanted St. Jude valves and is useful in identifying patients with prosthetic dysfunction.
No takes yet. Share an insight, caveat, or question.
Weinstein et al. (1983) conducted an observational in Implanted St. Jude prosthetic valves (n=23). St. Jude prosthetic valve vs. Native valves of healthy subjects was evaluated on Peak transprosthetic mitral flow velocity (m/sec) (p=<0.001). St. Jude prosthetic valves exhibited higher peak mitral flow velocities compared to native valves but similar pressure half-times.