Key result
Undergoing clinically indicated MRI scans in patients implanted with a SureScan MRI-conditional pacing system resulted in no MRI-related complications (0%).
Why the study?
Does undergoing MRI scans cause MRI-related complications in patients with an MRI-conditional pacing system?
Cohort (n=2,629)
Yes
Does undergoing MRI scans cause MRI-related complications in patients with an MRI-conditional pacing system?
Real-world prospective data confirms the safety of the Medtronic SureScan MRI-conditional pacing system for patients undergoing single or multiple MRI scans.
Answers are grounded in this paper and cite their sources.
Supports MRI safety with SureScan systems in real-world use; leaves open need for randomized confirmation before broader adoption.
OBJECTIVES: This global, multicenter, prospective study, initiated to meet U.S. Food and Drug Administration condition-of-approval requirements, evaluated the safety and efficacy of the Medtronic magnetic resonance imaging (MRI)-conditional pacing system when used in an MRI environment in routine clinical practice. The primary endpoint was MRI-related complications. The secondary endpoint was the cumulative change in pacing capture threshold (PCT) for patients undergoing multiple MRI scans. BACKGROUND: Large-scale, real-world evaluation of MRI in patients implanted with an MRI-conditional pacing system remains limited, with few published data for patients who undergo multiple MRI scans. METHODS: Patients were enrolled and followed up prospectively from the time of implantation. Evaluation of the pacemaker function was performed before and after MRI. The MRI-related complication-free rate was evaluated. Changes in electrical performance after each scan and cumulative changes over multiple scans were analyzed. RESULTS: In 81 centers, 2,629 patients were implanted with a complete SureScan pacing system (41.8% women, age 70.2 ± 12.5 years). A total of 526 patients (28.5%) received 872 clinically indicated MRI scans, including 58 thoracic scans. No MRI-related complications occurred during or after MRI, meeting the primary objective. Six (1%) MRI-related observations (atrial fibrillation, PCT increase, and chest symptoms) were reported. A total of 171 patients (32.5%) underwent 2 or more scans with no cumulative increase in PCT. CONCLUSIONS: This report constitutes the largest longitudinal MRI experience in patients implanted with an MRI-conditional pacing system. Results support the safety profile of the SureScan system and demonstrate for the first time that patients may safely undergo multiple MRI scans. (SureScan Post-Approval Study; NCT01299675).
No takes yet. Share an insight, caveat, or question.
Williamson et al. (2017) conducted a cohort in Patients with a magnetic resonance imaging conditional pacemaker system (n=2,629). Medtronic SureScan MRI-conditional pacing system and MRI scans was evaluated on MRI-related complications. Undergoing clinically indicated MRI scans in patients implanted with a SureScan MRI-conditional pacing system resulted in no MRI-related complications (0%).