Key result
First preinduction mean arterial pressure showed only a weak correlation with mean daytime mean arterial pressure (r = 0.429, P < 0.001), indicating it cannot be used as a surrogate.
Why the study?
Preinduction blood pressure may not reflect a patient's normal profile or usual range of blood pressures, motivating evaluation of the relationship between ambulatory and perioperative mean arterial pressures.
Observational (n=370)
Preinduction mean arterial pressure is a poor surrogate for normal daytime mean arterial pressure, and intraoperative pressures often fall below the lowest nighttime pressures in patients undergoing noncardiac surgery.
Answers are grounded in this paper and cite their sources.
Preinduction MAP is unreliable for estimating ambulatory values; leaves open optimal perioperative BP targets in noncardiac surgery.
BACKGROUND: Normal blood pressure varies among individuals and over the circadian cycle. Preinduction blood pressure may not be representative of a patient's normal blood pressure profile and cannot give an indication of a patient's usual range of blood pressures. This study therefore aimed to determine the relationship between ambulatory mean arterial pressure and preinduction, postinduction, and intraoperative mean arterial pressures. METHODS: Ambulatory (automated oscillometric measurements at 30-min intervals) and preinduction, postinduction, and intraoperative mean arterial pressures (1-min intervals) were prospectively measured and compared in 370 American Society of Anesthesiology physical status classification I or II patients aged 40 to 65 yr having elective noncardiac surgery with general anesthesia. RESULTS: There was only a weak correlation between the first preinduction and mean daytime mean arterial pressure (r = 0.429, P < 0.001). The difference between the first preinduction and mean daytime mean arterial pressure varied considerably among individuals. In about two thirds of the patients, the lowest postinduction and intraoperative mean arterial pressures were lower than the lowest nighttime mean arterial pressure. The difference between the lowest nighttime mean arterial pressure and a mean arterial pressure of 65 mmHg varied considerably among individuals. The lowest nighttime mean arterial pressure was higher than 65 mmHg in 263 patients (71%). CONCLUSIONS: Preinduction mean arterial pressure cannot be used as a surrogate for the normal daytime mean arterial pressure. The lowest postinduction and intraoperative mean arterial pressures are lower than the lowest nighttime mean arterial pressure in most patients.
No takes yet. Share an insight, caveat, or question.
Saugel et al. (2019) conducted an observational in Elective noncardiac surgery with general anesthesia (n=370). Preinduction mean arterial pressure vs. Ambulatory mean daytime mean arterial pressure was evaluated on Correlation between first preinduction and mean daytime mean arterial pressure (r = 0.429, p=< 0.001). First preinduction mean arterial pressure showed only a weak correlation with mean daytime mean arterial pressure (r = 0.429, P < 0.001), indicating it cannot be used as a surrogate.
Synapse has enriched 10 related papers. Consider them for comparative context: