Why the study?
How do blood pressure decreases during general anaesthesia compare to physiological decreases during natural sleep?
How do blood pressure decreases during general anaesthesia compare to physiological decreases during natural sleep?
Intra-operative blood pressure decreases are comparable to, though slightly greater than, physiological decreases seen during natural sleep, providing context for defining intra-operative hypotension.
Answers are grounded in this paper and cite their sources.
Offers physiological context for intra-operative hypotension definitions; leaves open whether thresholds warrant revision.
The scientific justification for particular values of intra-operative hypotension is poorly substantiated. To provide a rationale for appropriate values we recorded blood pressure measurements at home for 24 h using an automated non-invasive ambulatory blood pressure measurement device. These blood pressures were compared with blood pressure measured before and during general anaesthesia in 18 subjects undergoing elective day surgery. We confirmed that a pre-operative reading taken upon admission to hospital is significantly elevated compared to a usual daytime blood pressure in the same patient. The median (IQR [range]) increases in systolic and mean arterial pressures were 10 (2-15 [-5 to 59]) mmHg, p = 0.003 and 10 (5-14 [-5 to 35]) mmHg, p = 0.002, respectively. When using this admission blood pressure measurement as a 'baseline', systolic and mean arterial pressures decreased during sleep by 41 (30-46 [6-83]) mmHg and 34 (26-36 [6-58]) mmHg, respectively (p = 0.001). This decreased even further intra-operatively: systolic blood pressure by 49 (36-64 [15-96]) mmHg and mean arterial pressure by 36 (26-46 [8-66]) mmHg (p = 0.001).
No takes yet. Share an insight, caveat, or question.
Soo et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: