Key result
LVAD recipients demonstrated lower intrinsic right ventricular contractility and ventriculo-vascular coupling compared to healthy reference subjects.
Why the study?
Detecting right heart failure post LVAD is challenging, and sensitive pressure-volume loop assessments of RV contractility may improve appreciation of post-LVAD RV dysfunction.
Does LVAD support affect intrinsic right ventricular contractility and right ventricular-pulmonary arterial coupling compared to healthy controls?
Observational (n=33)
Yes
Does LVAD support affect intrinsic right ventricular contractility and right ventricular-pulmonary arterial coupling compared to healthy controls?
Answers are grounded in this paper and cite their sources.
Invasive pressure-volume loop measurements reveal occult intrinsic right ventricular dysfunction and diminished contractile reserve in LVAD patients, providing insight into late right heart failure.
BackgroundDetecting right heart failure post left ventricular assist device (LVAD) is challenging. Sensitive pressure-volume loop assessments of right ventricle (RV) contractility may improve our appreciation of post-LVAD RV dysfunction.MethodsThirteen LVAD patients and 20 reference (non-LVAD) subjects underwent comparison of echocardiographic, right heart cath hemodynamic, and pressure-volume loop-derived assessments of RV contractility using end-systolic elastance (Ees), RV afterload by effective arterial elastance (Ea), and RV-pulmonary arterial coupling (ratio of Ees/Ea).ResultsLVAD patients had lower RV Ees (0.20 ± 0.08 vs 0.30 ± 0.15 mm Hg/ml, p = 0.01) and lower RV Ees/Ea (0.37 ± 0.14 vs 1.20 ± 0.54, p < 0.001) versus reference subjects. Low RV Ees correlated with reduced RV septal strain, an indicator of septal contractility, in both the entire cohort (r = 0.68, p = 0.004) as well as the LVAD cohort itself (r = 0.78, p = 0.02). LVAD recipients with low RV Ees/Ea (below the median value) demonstrated more clinical heart failure (71% vs 17%, p = 0.048), driven by an inability to augment RV Ees (0.22 ± 0.11 vs 0.19 ± 0.02 mm Hg/ml, p = 0.95) to accommodate higher RV Ea (0.82 ± 0.38 vs 0.39 ± 0.08 mm Hg/ml, p = 0.002). Pulmonary artery pulsatility index (PAPi) best identified low baseline RV Ees/Ea (≤0.35) in LVAD patients ((area under the curve) AUC = 0.80); during the ramp study, change in PAPi also correlated with change in RV Ees/Ea (r = 0.58, p = 0.04).ConclusionsLVAD patients demonstrate occult intrinsic RV dysfunction. In the setting of excess RV afterload, LVAD patients lack the RV contractile reserve to maintain ventriculo-vascular coupling. Depression in RV contractility may be related to LVAD left ventricular unloading, which reduces septal contractility. Detecting right heart failure post left ventricular assist device (LVAD) is challenging. Sensitive pressure-volume loop assessments of right ventricle (RV) contractility may improve our appreciation of post-LVAD RV dysfunction. Thirteen LVAD patients and 20 reference (non-LVAD) subjects underwent comparison of echocardiographic, right heart cath hemodynamic, and pressure-volume loop-derived assessments of RV contractility using end-systolic elastance (Ees), RV afterload by effective arterial elastance (Ea), and RV-pulmonary arterial coupling (ratio of Ees/Ea). LVAD patients had lower RV Ees (0.20 ± 0.08 vs 0.30 ± 0.15 mm Hg/ml, p = 0.01) and lower RV Ees/Ea (0.37 ± 0.14 vs 1.20 ± 0.54, p < 0.001) versus reference subjects. Low RV Ees correlated with reduced RV septal strain, an indicator of septal contractility, in both the entire cohort (r = 0.68, p = 0.004) as well as the LVAD cohort itself (r = 0.78, p = 0.02). LVAD recipients with low RV Ees/Ea (below the median value) demonstrated more clinical heart failure (71% vs 17%, p = 0.048), driven by an inability to augment RV Ees (0.22 ± 0.11 vs 0.19 ± 0.02 mm Hg/ml, p = 0.95) to accommodate higher RV Ea (0.82 ± 0.38 vs 0.39 ± 0.08 mm Hg/ml, p = 0.002). Pulmonary artery pulsatility index (PAPi) best identified low baseline RV Ees/Ea (≤0.35) in LVAD patients ((area under the curve) AUC = 0.80); during the ramp study, change in PAPi also correlated with change in RV Ees/Ea (r = 0.58, p = 0.04). LVAD patients demonstrate occult intrinsic RV dysfunction. In the setting of excess RV afterload, LVAD patients lack the RV contractile reserve to maintain ventriculo-vascular coupling. Depression in RV contractility may be related to LVAD left ventricular unloading, which reduces septal contractility.
No takes yet. Share an insight, caveat, or question.
Scheel et al. (2023) conducted an observational in Left ventricular assist device (LVAD) recipients (n=33). Left ventricular assist device (LVAD) vs. Non-LVAD healthy reference subjects was evaluated on Right ventricular-pulmonary arterial coupling (Ees/Ea ratio) (p=<0.001). LVAD recipients demonstrated lower intrinsic right ventricular contractility and ventriculo-vascular coupling compared to healthy reference subjects.