Key result
During standing, the Bazett formula erroneously identified 62.05% of healthy children as having a prolonged QTc interval (>440 ms), compared to only 1.81% when using the Fridericia formula.
Why the study?
Children have higher heart rates than adults, and Bazett correction artificially prolongs QTc at increased heart rates during postural provocations, raising concerns about erroneously increased QTc values during paediatric LQTS screening.
Does the Bazett formula, compared to Fridericia and Framingham formulas, increase the incidence of falsely prolonged QTc intervals during postural screening in healthy children?
Cross-Sectional (n=332)
No
Does the Bazett formula, compared to Fridericia and Framingham formulas, increase the incidence of falsely prolonged QTc intervals during postural screening in healthy children?
Absolute Event Rate: 62.05% vs 1.81%
The Bazett formula produces a high rate of false-positive QTc prolongations in children during postural screening, suggesting the Fridericia formula should be preferred for pediatric ECGs.
Bazett formula may inflate false-positive QTc prolongations during standing in children; leaves open preferred correction method for pediatric ECGs.
BackgroundBazett formula is frequently used in paediatric screening for the long QT syndrome (LQTS) and proposals exist that using standing rather than supine electrocardiograms (ECG) improves the sensitivity of LQTS diagnosis. Nevertheless, compared to adults, children have higher heart rates (especially during postural provocations) and Bazett correction is also known to lead to artificially prolonged QTc values at increased heart rates. This study assessed the incidence of erroneously increased QTc values in normal children without QT abnormalities.MethodsContinuous 12-lead ECGs were recorded in 332 healthy children (166 girls) aged 10.7±2.6 years while they performed postural manoeuvring consisting of episodes (in the following order) of supine, sitting, standing, supine, standing, sitting, and supine positions, each lasting 10 minutes. Detailed analyses of QT/RR profiles confirmed the absence of prolonged individually corrected QTc interval in each child. Heart rate and QT intervals were measured in 10-second ECG segments and in each segment, QTc intervals were obtained using Bazett, Fridericia, and Framingham formulas. In each child, the heart rates and QTc values obtained during supine, sitting and standing positions were averaged. QTc durations by the three formulas were classified to <440 ms, 440-460 ms, 460-480 ms, and >480 ms. ResultsAt supine position, averaged heart rate was 77.5±10.5 beat per minute (bpm) and Bazett, Fridericia and Framingham QTc intervals were 425.3±15.8, 407.8±13.9, and 408.2±13.1 ms, respectively. At sitting and standing, averaged heart rate increased to 90.9±10.1 and 100.9±10.5 bpm, respectively. While Fridericia and Framingham formulas showed only minimal QTc changes, Bazett correction led to QTc increases to 435±15.1 and 444.9±15.9 ms at sitting and standing, respectively. At sitting, Bazett correction identified 51, 4, and 0 children as having the QTc intervals 440-460, 460-480, and >480 ms, respectively. At sitting, these numbers increased to 118, 11, and 1, while on standing these numbers were 151, 45, and 5, respectively. Irrespective of the postural position, Fridericia and Framingham formulas identified only a small number (<7) of children with QT interval between 440 and 460 ms and no children with longer QTc.ConclusionDuring screening for LQTS in children, the use of Bazett formula leads to a high number of false positive cases especially if the heart rates are increased (e.g. by postural manoeuvring). The use of Fridericia formula can be recommended to replace the Bazett correction not only for adult but also for paediatric ECGs.
No takes yet. Share an insight, caveat, or question.
Andršová et al. (2020) conducted a cross-sectional in Healthy children (screening for prolonged QTc) (n=332). Bazett QTc correction formula vs. Fridericia and Framingham QTc correction formulas was evaluated on Proportion of healthy children erroneously identified with QTc >440 ms during standing. During standing, the Bazett formula erroneously identified 62.05% of healthy children as having a prolonged QTc interval (>440 ms), compared to only 1.81% when using the Fridericia formula.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: