Key result
The novel eight-biomarker strip demonstrated good linear correlation with conventional clinical analyzers for detecting acute myocardial infarction markers, providing results in 15 minutes without sample pretreatment.
Why the study?
Accurate detection of markers in human serum is important in the early diagnosis of acute myocardial infarction.
Does a novel eight biomarker strip accurately detect acute myocardial infarction biomarkers in human serum compared to conventional clinical analyzers?
Does a novel eight biomarker strip accurately detect acute myocardial infarction biomarkers in human serum compared to conventional clinical analyzers?
A novel, rapid eight-biomarker strip provides accurate, quantitative detection of cardiac and lipid markers in human serum, offering a faster and simpler alternative to conventional analyzers for AMI diagnosis.
Answers are grounded in this paper and cite their sources.
Enables faster point-of-care AMI biomarker testing without pretreatment; extends multiplex validation beyond conventional analyzers.
Accurate detection of markers in human serum is important in the early diagnosis of acute myocardial infarction (AMI). This work presents a novel eight biomarker strip, which combines dry chemistry with a fluorescence lateral flow assay. Eight AMI markers were employed simultaneously for sensitive detection, including cholesterol (TC), triglyceride (TG), high density lipoprotein cholesterol (HDL-C) and low density lipoprotein cholesterol (LDL-C), uric acid (UA), myoglobin (Myo), creatine kinase-MB (CK-MB), and cardiac troponin I (cTnI). The strip offers the advantages of simple fabrication, convenience, time-saving detection and accurate assessment for AMI. Moreover, the strip possesses acceptable applicability for human serum. This proposed strategy establishes a remarkable platform for the construction of a multi-target detection strip that is feasible for accurate detection for real human serum samples.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2019) studied Acute myocardial infarction (n=30). Eight-biomarker diagnostic strip vs. Conventional clinical analyzers (Beckman AU5800 and Abbott i2000SR) was evaluated on Linear correlation between the eight-biomarker strip and clinical methods. The novel eight-biomarker strip demonstrated good linear correlation with conventional clinical analyzers for detecting acute myocardial infarction markers, providing results in 15 minutes without sample pretreatment.
Synapse has enriched 10 related papers. Consider them for comparative context: