Key result
Early serial measurements of cardiac troponin I (sensitivity 82.4%) were a more accurate predictor of coronary reperfusion 90 minutes after thrombolytic therapy than CK-MB (64.7%) and myoglobin.
Why the study?
Does early serial measurement of cardiac troponin I improve the noninvasive determination of coronary reperfusion compared to CK-MB and myoglobin in patients with acute myocardial infarction receiving thrombolytic therapy?
Observational (n=25)
Does early serial measurement of cardiac troponin I improve the noninvasive determination of coronary reperfusion compared to CK-MB and myoglobin in patients with acute myocardial infarction receiving thrombolytic therapy?
Early serial measurements of cardiac troponin I are a more accurate predictor of early coronary artery reperfusion 90 minutes after thrombolytic therapy compared to CK-MB and myoglobin.
Answers are grounded in this paper and cite their sources.
May aid noninvasive reperfusion assessment post-thrombolysis; hypothesis-generating and requires prospective validation.
The authors report the use of cardiac troponin I (cTnI) for the early, noninvasive determination of coronary reperfusion following thrombolytic therapy. Cardiac troponin I, creatine kinase (CK)-MB, and myoglobin concentrations were measured in early serum specimens at 30, 60, and 90 minutes after initiation of therapy (0 minutes) in 25 consecutive patients given front-loaded rt-PA during acute myocardial infarction. Angiography, determined at 90 minutes after therapy, was used to classify patients as follows: group I (n = 17) reperfusion (TIMI flow grade 2, 3); and group 2 (n = 8) absence of reperfusion (TIMI flow grade 0, 1). The authors calculated the ratio increase in cTnI (delta cTnI), CK-MB (delta CK-MB), and myoglobin (delta myoglobin) 90 minutes after therapy in group 1 and 2. Serum cTnI, CK-MB and myoglobin concentrations significantly increased at 60 and 90 minutes in group 1, but not in group 2. Delta cTnI, delta CK-MB, and delta myoglobin levels were significantly increased in group 1 versus group 2 at 90 minutes. Further, delta cTnI was significantly greater at 90 minutes within group 1 compared to delta CK-MB and delta myoglobin. The sensitivity for detecting reperfusion at 90 minutes angiography using threshold values of 6.0 for delta cTnI, 7.0 for delta CK-MB, and 5.0 for delta myoglobin were: delta cTnI 82.4%; delta CK-MB 64.7%; delta myoglobin 76.5%; respectively. This study indicates that early serial measurements of cTnI were a more accurate predictor of early coronary artery reperfusion 90 minutes after thrombolytic therapy compared to CK-MB and myoglobin. Larger population studies will be necessary to confirm these finding.
No takes yet. Share an insight, caveat, or question.
Apple et al. (1996) conducted an observational in Acute myocardial infarction (n=25). Early monitoring of serum cardiac troponin I (cTnI) vs. CK-MB and myoglobin was evaluated on Sensitivity for detecting reperfusion at 90 minutes angiography. Early serial measurements of cardiac troponin I (sensitivity 82.4%) were a more accurate predictor of coronary reperfusion 90 minutes after thrombolytic therapy than CK-MB (64.7%) and myoglobin.