Key result
The location-centric method for detecting phase singularity in cardiac fibrillation was highly robust and 28.6-fold faster than the conventional Iyer-Gray method in a 2D mathematical model.
Why the study?
Does the location-centric method improve computational efficiency and robustness for detecting phase singularity in a 2D mathematical model of AF compared to the Iyer-Gray method?
Does the location-centric method improve computational efficiency and robustness for detecting phase singularity in a 2D mathematical model of AF compared to the Iyer-Gray method?
Answers are grounded in this paper and cite their sources.
A novel location-centric algorithm significantly reduces computation time for detecting phase singularities in atrial fibrillation models while maintaining accuracy, which may facilitate real-time rotor mapping in clinical electrophysiology.
BACKGROUND: The point of phase singularity (PS) is considered to represent a spiral wave core or a rotor in cardiac fibrillation. Computational efficiency is important for detection of PS in clinical electrophysiology. We developed a novel algorithm for highly efficient and robust detection of PS. METHODS: In contrast to the conventional method, which calculates PS based on the line integral of the phase around a PS point equal to ±2π (the Iyer-Gray method), the proposed algorithm (the location-centric method) looks for the phase discontinuity point at which PS actually occurs. We tested the efficiency and robustness of these two methods in a two-dimensional mathematical model of atrial fibrillation (AF), with and without remodeling of ionic currents. RESULTS: 1. There was a significant association, in terms of the Hausdorff distance (3.30 ± 0.0 mm), between the PS points measured using the Iyer-Gray and location-centric methods, with almost identical PS trajectories generated by the two methods. 2. For the condition of electrical remodeling of AF (0.3 × ICaL), the PS points calculated by the two methods were satisfactorily co-localized (with the Hausdorff distance of 1.64 ± 0.09 mm). 3. The proposed location-centric method was substantially more efficient than the Iyer-Gray method, with a 28.6-fold and 28.2-fold shorter run times for the control and remodeling scenarios, respectively. CONCLUSION: We propose a new location-centric method for calculating PS, which is robust and more efficient compared with the conventionally used method.
No takes yet. Share an insight, caveat, or question.
Lee et al. (2016) studied Cardiac fibrillation. Location-centric method vs. Iyer-Gray method was evaluated on Computational run time and spatial agreement (Hausdorff distance) (28.6-fold shorter run time). The location-centric method for detecting phase singularity in cardiac fibrillation was highly robust and 28.6-fold faster than the conventional Iyer-Gray method in a 2D mathematical model.
Synapse has enriched 10 related papers. Consider them for comparative context: