Key result
In patients with Stanford type B acute aortic dissection, a non-communicating false lumen was associated with a lower rate of in-hospital death compared to a communicating false lumen.
Why the study?
Does a non-communicating false lumen reduce in-hospital death in patients with acute type B aortic dissection?
Cohort (n=502)
Yes
Does a non-communicating false lumen reduce in-hospital death in patients with acute type B aortic dissection?
In patients with acute type B aortic dissection, a non-communicating false lumen is associated with older age, less distal extension, and significantly lower in-hospital mortality compared to a communicating false lumen.
Answers are grounded in this paper and cite their sources.
Non-communicating false lumen may aid risk stratification in type B dissection; leaves open prospective validation before guiding management.
BACKGROUND: In practice, patients with acute aortic dissection (AAD) are generally divided into 2 groups according to the status of the false lumen: non-communicating or communicating. The similarities and differences between the 2 groups, however, have not been fully determined in a large population. METHODS AND RESULTS: We studied 502 patients with Stanford type B AAD. Clinical background at symptom onset was compared, and similarities and differences characterized, for patients with non-communicating (NC group, n=288) vs. communicating (C group, n=214) false lumens. Time of day (00.00-06.00 hours, 06.00-12.00 hours, 12.00-18.00 hours, and 18.00-24.00 hours) and extent of physical activity (extreme exertion, slight exertion, at rest, and sleeping) at symptom onset were similar between groups. Patients in the NC group were older (mean age, 71±11 years vs. 64±14 years, P<0.01) and had lower prevalence of distally extended aortic dissection (26% vs. 8%, P<0.01) and deaths in hospital (2% vs. 7%, P=0.011) than those in the C group. CONCLUSIONS: At symptom onset, clinical circumstances and physical activity were similar between the groups, and old age and a background of DeBakey IIIa aortic dissection may be associated with determination of false lumen status. The outcome in the NC group was better than in the C group.
No takes yet. Share an insight, caveat, or question.
Akutsu et al. (2015) conducted a cohort in Stanford type B acute aortic dissection (n=502). Non-communicating false lumen vs. Communicating false lumen was evaluated on In-hospital death (p=0.011). In patients with Stanford type B acute aortic dissection, a non-communicating false lumen was associated with a lower rate of in-hospital death compared to a communicating false lumen.
Synapse has enriched 10 related papers. Consider them for comparative context: