Key result
Partial thrombosis of the false lumen in patients with uncomplicated type B aortic dissection was associated with a higher annual aortic growth rate compared to a patent false lumen.
Why the study?
Does partial thrombosis of the false lumen increase aortic expansion in patients with acute type B aortic dissection?
Cohort (n=84)
Yes
Does partial thrombosis of the false lumen increase aortic expansion in patients with acute type B aortic dissection?
The study aims to determine if partial thrombosis of the false lumen in acute type B aortic dissection is associated with increased aortic expansion.
Answers are grounded in this paper and cite their sources.
Should not yet alter surveillance in acute type B dissection; hypothesis-generating for partial false lumen thrombosis and expansion.
In the acute setting, the majority of patients affected by uncomplicated acute type B aortic dissection (ABAD) can be managed with medical therapy. In these patients, inhospital outcome is generally acceptable, with mortality rates of 1-10% (1,2). However, long-term outcomes in this group is less positive, with a mortality rates reported as 2025% within 3 years. Predictors of long-term complications have been a highly debated topic in recent years. Reports from the International Registry of Acute Aortic Dissection (IRAD) have shown that a partially thrombosed false lumen is associated with increased surgical mortality. Among ABAD patients discharged alive, those presenting with a partially thrombosed false lumen had an increased rate of mortality, after adjusting for age, gender and type of in-hospital treatment (3). One hypothesis for this observation is that partial thrombosis of the false lumen may occlude distal re-entry tears (“sac formation”), resulting in higher diastolic pressure (4). The purpose of this study was to determine whether partial thrombosis of the false lumen in ABAD patients is associated with increased aortic expansion (5).
No takes yet. Share an insight, caveat, or question.
Tolenaar et al. (2014) conducted a cohort in Uncomplicated acute type B aortic dissection (n=84). Partial thrombosis of the false lumen vs. Patent false lumen was evaluated on Annual aortic growth rate (MD 2.05 mm/year, 95% CI 0.10 to 4.01, p=0.040). Partial thrombosis of the false lumen in patients with uncomplicated type B aortic dissection was associated with a higher annual aortic growth rate compared to a patent false lumen.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: