Key result
The proposed task-unified network achieved competitive performance in left ventricular quantification, yielding average mean absolute errors of 132 mm2 for area, 1.78 mm for cavity dimension, and 1.16 mm for regional wall thickness.
Why the study?
Accurate automatic left ventricular quantification remains challenging due to dynamic cardiac anatomy, and existing direct regression methods lack visual-based analysis.
Does a task-unified network with transformer and spatial-temporal convolution improve automated left ventricular quantification from cardiac MRI?
Does a task-unified network with transformer and spatial-temporal convolution improve automated left ventricular quantification from cardiac MRI?
A novel task-unified deep learning network combining transformer and spatial-temporal convolution achieves high accuracy in automated left ventricular segmentation and quantification from cardiac MRI.
Hypothesis-generating for automated LV quantification on CMR; prospective clinical validation required before adoption.
Quantification of the cardiac function is vital for diagnosing and curing the cardiovascular diseases. Left ventricular function measurement is the most commonly used measure to evaluate the function of cardiac in clinical practice, how to improve the accuracy of left ventricular quantitative assessment results has always been the subject of research by medical researchers. Although considerable efforts have been put forward to measure the left ventricle (LV) automatically using deep learning methods, the accurate quantification is yet a challenge work as a result of the changeable anatomy structure of heart in the systolic diastolic cycle. Besides, most methods used direct regression method which lacks of visual based analysis. In this work, a deep learning segmentation and regression task-unified network with transformer and spatial-temporal convolution was proposed to segment and quantify the LV simultaneously. The segmentation module leveraged a U-Net like 3D Transformer model to predict the contour of three anatomy structures, while the regression module learned spatial-temporal representations from the original images and the reconstruct feature maps from segmentation path to estimate the fifinally desired quantification metrics. Furthermore, we employed a joint task loss function to train the two module networks. Our framework is evaluated on the MICCAI 2017 Left Ventricle Full Quantification Challenge dataset. The results of experiments demonstrate the effectiveness of our framework, which achieves competitive cardiac quantification metric results and at the same time produces visualized segmentation results that are conducive to later analysis.
No takes yet. Share an insight, caveat, or question.
Li et al. (2023) studied Cardiovascular diseases (n=145). Task-unified network with transformer and spatial-temporal convolution vs. Other state-of-the-art deep learning methods was evaluated on Mean absolute error (MAE) and Pearson correlation coefficient (PCC) for left ventricular indices. The proposed task-unified network achieved competitive performance in left ventricular quantification, yielding average mean absolute errors of 132 mm2 for area, 1.78 mm for cavity dimension, and 1.16 mm for regional wall thickness.