Key result
Custom wrist-worn device tracks post-exercise heart rate recovery within ~7 bpm of reference ECG.
Why the study?
Stair climbing is a common daily activity that could serve as an alternative test to assess cardiovascular autonomic function, prompting the evaluation of estimating heart rate recovery parameters after stair climbing using a wrist-worn device.
Can a wrist-worn device accurately estimate heart rate recovery parameters after stair climbing compared to a reference ECG in healthy volunteers?
Observational (n=54)
No
Can a wrist-worn device accurately estimate heart rate recovery parameters after stair climbing compared to a reference ECG in healthy volunteers?
Answers are grounded in this paper and cite their sources.
A wrist-worn device with photoplethysmography and barometric sensors can estimate heart rate recovery parameters after stair climbing, offering a potential unobtrusive method for monitoring cardiovascular autonomic function.
Heart rate recovery (HRR) after physical exercise is a convenient method to assess cardiovascular autonomic function. Since stair climbing is a common daily activity, usually followed by a slow walking or rest, this type of activity can be considered as an alternative HRR test. The present study explores the feasibility to estimate HRR parameters after stair climbing using a wrist-worn device with embedded photoplethysmography and barometric pressure sensors. A custom-made wrist-worn device, capable of acquiring heart rate and altitude, was used to estimate the time-constant of exponential decay τ , the short-term time constant S , and the decay of heart rate in 1 min D . Fifty-four healthy volunteers were instructed to climb the stairs at three different climbing rates. When compared to the reference electrocardiogram, the absolute and percentage errors were found to be ≤ 21.0 s (≤ 52.7%) for τ , ≤ 0.14 (≤ 19.2%) for S , and ≤ 7.16 bpm (≤ 20.7%) for D in 75% of recovery phases available for analysis. The proposed approach to monitoring HRR parameters in an unobtrusive way may complement information provided by personal health monitoring devices (e.g., weight loss, physical activity), as well as have clinical relevance when evaluating the efficiency of cardiac rehabilitation program outside the clinical setting.
No takes yet. Share an insight, caveat, or question.
Sokas et al. (2019) conducted an observational in Healthy volunteers (n=54). Custom wrist-worn device with photoplethysmography and barometric pressure sensors vs. Reference electrocardiogram (ECG) was evaluated on Agreement of heart rate recovery parameters (time-constant τ, short-term time constant S, and decay in 1 min D) between the wrist-worn device and reference ECG (Absolute errors ≤ 21.0 s for τ, ≤ 0.14 for S, and ≤ 7.16 bpm for D in 75% of recovery phases). A custom wrist-worn device estimated heart rate recovery parameters after stair climbing with absolute errors of ≤7.16 bpm for 1-minute decay in 75% of recovery phases compared to reference ECG.