Key result
Home blood pressure measurements correlated well with 24-h ABPM in hypertensive women, with stronger correlation in White American than African-American women.
Why the study?
Are clinic and home blood pressure measurements reliable and reproducible compared to 24-h ABPM in hypertensive women across different ages and ethnicities?
Observational (n=161)
Are clinic and home blood pressure measurements reliable and reproducible compared to 24-h ABPM in hypertensive women across different ages and ethnicities?
Home blood pressure measurements are reliable compared to 24-hour ABPM in both African-American and White hypertensive women, supporting their use in clinical practice despite some variations in correlation strength by age and ethnicity.
Answers are grounded in this paper and cite their sources.
Home BP may approximate ABPM in hypertensive women; leaves open ethnic differences and requires prospective validation before practice change.
BACKGROUND: The purposes of this study were to establish the reproducibility and reliability of clinic and home blood pressure readings and to determine whether correlations differed according to age and ethnicity. METHODS: Blood pressure readings taken in a clinical setting and at home from 161 hypertensive women who were either younger or older (including 91 White American and 61 African-American) were compared with 24-h ambulatory blood pressure monitoring (ABPM) readings (considered the gold standard of blood pressure measurement). RESULTS: Bland-Altman statistical method showed good levels of agreement between clinic blood pressures measured 30 days apart, and blood pressures measured at home in the morning over a 30-day program, when compared with mean 24-h ABPM readings. On examining individual Bland-Altman plots for younger and older women, White American and African-American women's blood pressures were well correlated for home measures and 24-h ABPM readings. The correlation between daytime systolic home blood pressure readings and systolic 24-h ABPM readings was much stronger for White American women (r=0.75) than for African-American women (r=0.57). There were also correlation differences in mean systolic blood pressure between home blood pressure readings and 24-h ABPM readings according to age (r=0.66 for younger and r=0.72 for older). CONCLUSION: These results support current research findings that home blood pressure measurements are reliable when compared with 24-h ABPM readings both in African-American and White women.
No takes yet. Share an insight, caveat, or question.
Scisney‐Matlock et al. (2009) conducted an observational in hypertension (n=161). Clinic and home blood pressure measurements vs. 24-h ambulatory blood pressure monitoring (ABPM) was evaluated on Correlation between daytime systolic home blood pressure readings and systolic 24-h ABPM readings (r=0.75 (White American) vs r=0.57 (African-American)). Home blood pressure measurements correlated well with 24-h ABPM in hypertensive women, with stronger correlation in White American than African-American women.
Synapse has enriched 10 related papers. Consider them for comparative context: