Key result
3D Black Blood TSE SPACE imaging yielded comparable qualitative and quantitative measurements to 2D TSE for carotid and aortic arteries, but was suboptimal for femoral imaging.
Why the study?
Does 3D black blood magnetic resonance imaging SPACE provide comparable evaluation of atherosclerotic plaques compared to conventional 2D multi-contrast TSE sequences in patients at risk for cardiovascular disease?
Cross-Sectional (n=16)
Does 3D black blood magnetic resonance imaging SPACE provide comparable evaluation of atherosclerotic plaques compared to conventional 2D multi-contrast TSE sequences in patients at risk for cardiovascular disease?
3D black blood TSE SPACE provides comparable qualitative and quantitative measurements to 2D TSE for evaluating atherosclerotic plaques in the carotids and aorta, suggesting it is a feasible imaging approach.
Supports 3D SPACE for efficient carotid/aortic plaque MRI; leaves open prospective outcome validation before wider adoption.
AIM: To compare 3D Black Blood turbo spin echo (TSE) sampling perfection with application-optimized contrast using different flip angle evolution (SPACE) vs 2D TSE in evaluating atherosclerotic plaques in multiple vascular territories. METHODS: The carotid, aortic, and femoral arterial walls of 16 patients at risk for cardiovascular or atherosclerotic disease were studied using both 3D black blood magnetic resonance imaging SPACE and conventional 2D multi-contrast TSE sequences using a consolidated imaging approach in the same imaging session. Qualitative and quantitative analyses were performed on the images. Agreement of morphometric measurements between the two imaging sequences was assessed using a two-sample t-test, calculation of the intra-class correlation coefficient and by the method of linear regression and Bland-Altman analyses. RESULTS: No statistically significant qualitative differences were found between the 3D SPACE and 2D TSE techniques for images of the carotids and aorta. For images of the femoral arteries, however, there were statistically significant differences in all four qualitative scores between the two techniques. Using the current approach, 3D SPACE is suboptimal for femoral imaging. However, this may be due to coils not being optimized for femoral imaging. Quantitatively, in our study, higher mean total vessel area measurements for the 3D SPACE technique across all three vascular beds were observed. No significant differences in lumen area for both the right and left carotids were observed between the two techniques. Overall, a significant-correlation existed between measures obtained between the two approaches. CONCLUSION: Qualitative and quantitative measurements between 3D SPACE and 2D TSE techniques are comparable. 3D-SPACE may be a feasible approach in the evaluation of cardiovascular patients.
No takes yet. Share an insight, caveat, or question.
Stephanie Wong (2014) conducted a cross-sectional in At risk for cardiovascular or atherosclerotic disease (n=16). 3D Black Blood TSE SPACE vs. 2D multi-contrast TSE was evaluated on Qualitative and quantitative differences in atherosclerotic plaque evaluation. 3D Black Blood TSE SPACE imaging yielded comparable qualitative and quantitative measurements to 2D TSE for carotid and aortic arteries, but was suboptimal for femoral imaging.