Key result
Radiofrequency catheter ablation of premature ventricular complexes originating from the aortic cusp region did not increase the degree of aortic valve regurgitation at 3 months follow-up.
Why the study?
Conflicting results exist regarding the effect of radiofrequency catheter ablation of aortic cusp premature ventricular complexes on aortic valve regurgitation.
Does radiofrequency catheter ablation of aortic cusp premature ventricular complexes increase the risk of aortic valve regurgitation?
Cross-Sectional (n=54)
No
Does radiofrequency catheter ablation of aortic cusp premature ventricular complexes increase the risk of aortic valve regurgitation?
Radiofrequency catheter ablation of premature ventricular complexes originating from the aortic cusp region appears safe and does not cause significant aortic valve regurgitation at 3 months.
Answers are grounded in this paper and cite their sources.
Aortic cusp PVC ablation showed no short-term AR increase; leaves open long-term safety and need for prospective confirmation.
Aims: There are conflicting results about the effect of radiofrequency catheter ablation (RFA) of aortic cusp premature ventricular complexes (PVCs) on aortic valve regurgitation (AR). We aimed to investigate the effect of aortic valve function and integrity of RFA of coronary cusp PVCs. Methods: This cross-sectional study included 54 patients who underwent RFA of the aortic cusp region within the specified indications. Basal echocardiography was performed at baseline and 3 months after radiofrequency catheter ablation of aortic cusp PVCs. An increase of more than 1 degree in AR was considered significant. Results: The mean age of the patients was 44.6±12.0 years and the male gender ratio was 42.6%. On 24-hour rhythm holter monitoring, the mean VES burden was 21.5%, of which 12.9% were right coronary cusp (RCC), 59.3% left coronary cusp (LCC), and 27.8% RCC-LCC junction. Total procedure time was 136.9±33.2 minutes and RFA time was 14.9±11.4 minutes. When pre- and post-ablation parameters were compared, left ventricular ejection fraction was found to be higher after the procedure than before the procedure (p0.05). Conclusion: There was no increase in the degree of AR as a procedure-related complication and no significant AR was determined in patients who underwent RFA for PVCs in the aortic cusp region. Therefore, it can be concluded that VES ablations in the aortic cusp region are safe for the development of AR.
No takes yet. Share an insight, caveat, or question.
ZENGİN et al. (2023) conducted a cross-sectional in Premature ventricular complexes originating from coronary cusps (n=54). Radiofrequency catheter ablation vs. Pre-ablation baseline was evaluated on Increase of more than 1 degree in aortic valve regurgitation (p=>0.05). Radiofrequency catheter ablation of premature ventricular complexes originating from the aortic cusp region did not increase the degree of aortic valve regurgitation at 3 months follow-up.