Key result
In a single patient with advanced heart failure, increasing PEEP settings during adaptive servo-ventilation decreased cardiac index and parasympathetic activity while increasing sympathetic activity.
Why the study?
Does a PEEP ramp test during adaptive servo-ventilation optimize hemodynamics and autonomic nerve activity in a patient with advanced heart failure?
Case Report (n=1)
No
Does a PEEP ramp test during adaptive servo-ventilation optimize hemodynamics and autonomic nerve activity in a patient with advanced heart failure?
This initial case report suggests that a PEEP ramp test using real-time heart rate variability assessment may help identify optimal, patient-specific pressure settings during adaptive servo-ventilation to avoid adverse hemodynamic and autonomic effects.
BACKGROUND: Adaptive servo-ventilation (ASV) therapy is a recent non-invasive positive pressure ventilation therapy that was developed for patients with heart failure (HF) refractory to optimal medical therapy. However, it is likely that ASV therapy at relatively higher pressure setting worsens some of the patients' prognosis compared with optimal medical therapy. Therefore, identification of optimal pressure settings of ASV therapy is warranted. CASE PRESENTATION: We present the case of a 42-year-old male with HF, which was caused by dilated cardiomyopathy, who was admitted to our institution for evaluating his eligibility for heart transplantation. To identify the optimal pressure setting [peak end-expiratory pressure (PEEP) ramp test], we performed an ASV support test, during which the PEEP settings were set at levels ranging from 4 to 8 mmHg, and a heart rate variability (HRV) analysis using the MemCalc power spectral density method. Clinical parameters varied dramatically during the PEEP ramp test. Over incremental PEEP levels, pulmonary capillary wedge pressure, cardiac index and high-frequency level (reflecting parasympathetic activity) decreased; however, the low-frequency level increased along with increase in plasma noradrenaline concentrations. CONCLUSIONS: An inappropriately high PEEP setting may stimulate sympathetic nerve activity accompanied by decreased cardiac output. This was the first report on the PEEP ramp test during ASV therapy. Further research is warranted to determine whether use of optimal pressure settings using HRV analyses may improve the long-term prognosis of such patients.
No takes yet. Share an insight, caveat, or question.
Imamura et al. (2017) conducted a case report in Heart failure (n=1). Adaptive servo-ventilation (ASV) with PEEP ramp test was evaluated on Hemodynamics and heart rate variability. In a single patient with advanced heart failure, increasing PEEP settings during adaptive servo-ventilation decreased cardiac index and parasympathetic activity while increasing sympathetic activity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:
More on HFrEF treatmentMore from BMC Cardiovascular Disorders