Key result
Parahisian pacing in a patient with WPW syndrome demonstrated simultaneous atrial capture and pure His capture with underlying distal antegrade right bundle branch block.
Why the study?
Parahisian pacing differentiates routes of ventriculoatrial conduction during electrophysiology study of supraventricular tachycardia, but atypical capture responses can lead to erroneous conclusions.
Case Report (n=1)
Highlights the various complex responses that can occur during Parahisian pacing in WPW syndrome, emphasizing the need for careful interpretation to avoid erroneous conclusions.
Answers are grounded in this paper and cite their sources.
Case report underscores need for careful parahisian pacing interpretation in WPW; leaves open standardized criteria for complex responses.
Parahisian pacing (PHP) is a useful maneuver during electrophysiology study of supraventricular tachycardia (SVT) especially when the tachycardia is non-sustained. Various responses during PHP can differentiate between the routes of VA conduction (VAC). In a case of WPW syndrome with orthodromic re-entrant tachycardia, we encountered various responses which one must be cognizant about to avoid erroneous conclusions. Along with para-hisian capture and only ventricular capture, simultaneous atrial capture (SAC) and pure His capture were also noted. Moreover, during pure-His capture underlying distal antegrade right bundle branch block (RBBB) was encountered making it an intriguing case.
No takes yet. Share an insight, caveat, or question.
Bera et al. (2021) conducted a case report in WPW syndrome with orthodromic re-entrant tachycardia (n=1). Parahisian pacing was evaluated. Parahisian pacing in a patient with WPW syndrome demonstrated simultaneous atrial capture and pure His capture with underlying distal antegrade right bundle branch block.