Answers are grounded in this paper and cite their sources.
In this paper, a generalized optimal fault-tolerant control (FTC) technique is proposed for open-circuit faults in five-phase permanent-magnet (PM) machine drives. The proposed FTC technique considers pentagon and pentacle connections of stator windings in addition to conventional star connection. Open-circuit faults in stator windings of the machine as well as switches of the inverter are analyzed. The optimization objective is to produce ripple-free electromagnetic torque with minimum ohmic losses under open-circuit fault conditions. This is achieved by a simple closed-form equation to calculate reference optimal currents in all cases where a lookup table is utilized to represent the effect of fault type. The proposed FTC technique is easily extended to PM machines with higher number of phases. Experimental results for a five-phase PM machine drive are provided to demonstrate the proposed FTC strategy. In addition to single and double faults, which are analyzed for five-phase machine with star connection, triple-phase faults are also considered in pentagon and pentacle connections.
No takes yet. Share an insight, caveat, or question.
Mohammadpour et al. (2013) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: