Key result
Carotid Doppler PSV and VTI indices predict acute anterior ischemic stroke with ~13-fold higher odds.
Why the study?
Conventional imaging for acute ischemic stroke is limited by cost, accessibility, and transport, while the utility of bedside carotid Doppler ultrasound in detecting hemodynamic changes—particularly without structural stenosis—requires further evaluation.
Does bedside carotid Doppler ultrasound accurately diagnose acute anterior ischemic stroke?
Case-Control (n=128)
Does bedside carotid Doppler ultrasound accurately diagnose acute anterior ischemic stroke?
Odds Ratio: 13.461
p-value: p=< 0.001
Carotid Doppler ultrasound measurement of VTI and PSV indices provides a non-invasive, bedside diagnostic tool for acute anterior ischemic stroke.
May support bedside carotid Doppler for AAIS prediction; leaves open prospective validation before clinical adoption.
Background Acute ischemic stroke is a leading cause of mortality and long‐term disability. Conventional imaging methods like CT and MRI, while essential, are limited by cost, accessibility, and the need for patient transport. Carotid Doppler ultrasonography is a non‐invasive, low‐cost tool that can be performed bedside, yet its utility in detecting hemodynamic changes in acute ischemic stroke—particularly in the absence of structural stenosis—requires further evaluation. Methods This prospective case‐control study included 64 acute anterior ischemic stroke (AAIS) patients and 64 healthy controls. Using bedside carotid Doppler ultrasound, bilateral measurements of velocity time integral (VTI), peak systolic velocity (PSV), and arterial diameter were obtained. VTI and PSV indices were calculated as the percentage difference between right and left sides. Diagnostic accuracy was assessed through receiver operating characteristic (ROC) analysis and logistic regression. Results The AAIS group showed significantly higher VTI and PSV indices compared to controls ( p < 0.001). ROC analysis demonstrated good diagnostic performance (area under curve: 0.789 for VTI and 0.865 for PSV). At optimal cut‐off values (VTI > 5.1%; PSV > 6.35%), sensitivity and specificity exceeded 73% for both. Logistic regression identified both indices as independent predictors of AAIS (OR: 6.948 for VTI, OR: 13.461 for PSV), and the combined model explained 53.7% of stroke likelihood (Nagelkerke R 2 = 0.537). Conclusion VTI and PSV indices measured by carotid Doppler ultrasound are effective, noninvasive diagnostic tools for AAIS. Their bedside applicability makes them especially valuable in emergency settings where rapid decision‐making is crucial.
No takes yet. Share an insight, caveat, or question.
Acar et al. (2025) conducted a case-control in Acute anterior ischemic stroke (n=128). Carotid Doppler ultrasound VTI and PSV indices vs. Healthy controls was evaluated on Diagnosis of acute anterior ischemic stroke (OR 13.461 for PSV (OR 6.948 for VTI), p=< 0.001). Carotid Doppler ultrasound VTI and PSV indices independently predicted acute anterior ischemic stroke (OR 6.948 for VTI, OR 13.461 for PSV; p<0.001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: