Key result
Pulsed Doppler combined with cross-sectional echocardiography demonstrated a diagnostic reliability of ≥90% and accurately assessed the severity of prosthetic valve dysfunction in 86% of cases.
Why the study?
Does pulsed Doppler combined with cross-sectional echocardiography accurately diagnose and evaluate the severity of prosthetic valve dysfunction compared to invasive procedures?
Observational (n=103)
Does pulsed Doppler combined with cross-sectional echocardiography accurately diagnose and evaluate the severity of prosthetic valve dysfunction compared to invasive procedures?
Pulsed Doppler combined with cross-sectional echocardiography provides an accurate non-invasive assessment of prosthetic valve dysfunction, including localization and severity.
Answers are grounded in this paper and cite their sources.
Supports non-invasive prosthetic valve assessment; leaves open prospective validation against invasive standards.
Thirty patients with 33 mitral or aortic prostheses or both were examined using the pulsed Doppler technique combined with cross sectional echocardiography to study the applicability of the Doppler technique in the diagnosis and evaluation of the severity of prosthetic dysfunction and to assess the ability of the mapping procedure to estimate the site and the size of the prosthetic defect. The dysfunction was valvar regurgitation in 29 instances and stenoses in eight, all of which were confirmed by invasive procedures. The severity of the dysfunction was graded on a three point scale. A control group of 73 subjects with 88 normal prostheses also underwent pulsed Doppler and cross sectional echocardiography. The pulsed Doppler study followed the usual procedure for a valvar disease including two and three dimensional mapping for regurgitation. Eight patients also underwent a continuous wave Doppler examination. The diagnostic reliability of the pulsed Doppler technique was greater than or equal to 90%. The severity of the dysfunction was accurately assessed in 86% of cases. In the case of aortic regurgitation, mapping of the jets was performed as easily for prostheses as for native regurgitant valves. In the case of mitral regurgitation, the mapping patterns depended on the cause of the dysfunction. With valvar tears, a jet was detected at the centre of the annulus, and with paravalvar leaks eccentric atrial jets were seen opposite the site of the leak. The pulsed Doppler and the surgical findings correlated well for both the site of the dysfunction (16/20 (80%) patients) and the size of the leak (13/16 (81%) patients). Thus, despite some limitations, pulsed Doppler and particularly the mapping procedure provide sufficient information to give an accurate non-invasive assessment of prosthetic valve dysfunction.
No takes yet. Share an insight, caveat, or question.
Veyrat et al. (1985) conducted an observational in Valvar prosthetic dysfunction (n=103). Pulsed Doppler technique combined with cross-sectional echocardiography vs. Invasive procedures and surgical findings (reference standard) was evaluated on Diagnostic reliability and accuracy in assessing severity, site, and size of prosthetic dysfunction. Pulsed Doppler combined with cross-sectional echocardiography demonstrated a diagnostic reliability of ≥90% and accurately assessed the severity of prosthetic valve dysfunction in 86% of cases.
Synapse has enriched 10 related papers. Consider them for comparative context: