Key result
Double 120-second cryoballoon freeze linked to ~25-point lower safety event rate vs. single 240-second freeze.
Why the study?
A double 120 s freeze cryoballoon pulmonary vein isolation protocol proved non-inferior to a double 240 s protocol for AF recurrences, but whether it increases procedural safety was unknown.
Does a double 120-second freeze cryoballoon protocol improve procedural safety compared to a single 240-second freeze protocol in patients undergoing pulmonary vein isolation for atrial fibrillation?
Cohort (n=160)
No
Does a double 120-second freeze cryoballoon protocol improve procedural safety compared to a single 240-second freeze protocol in patients undergoing pulmonary vein isolation for atrial fibrillation?
A modified double 120-second freeze cryoballoon ablation protocol offers superior procedural safety without compromising acute isolation efficacy compared to the standard 240-second approach.
Answers are grounded in this paper and cite their sources.
Double 120s protocol associated with fewer energy-related events in cryoballoon PVI; leaves open need for randomized confirmation.
BACKGROUND: Recently a double 120 s freeze cryoballoon (CB) pulmonary vein isolation (PVI) protocol proved to be non inferior to a double 240 s freeze protocol in terms of atrial fibrillation (AF) recurrences. We hypothesized that this approach could also result in an increased procedure safety. METHODS: Eighty consecutive patients treated with a double 120 s freeze protocol (Group CB120) were compared with 80 previous consecutive patients treated with a single 240 s freeze protocol (Group CB240). Procedures were performed with a temperature probe to monitor the luminal esophageal temperature (LET), using a cut off for cryoenergy interruption of 15°C. During ablation at the septal pulmonary veins (PVs), the phrenic nerve (PN) function was monitored by pacing. RESULTS: In CB120 and CB240 the rate of single shot isolation was similar in all PVs. Time to isolation was not different between the two groups. Mean minimal esophageal temperature was lower in LSPV and LIPV of the CB240 group. A total of 4/80 patients (5%) of the CB120 group experienced a PN injury, but no persistent form was recorded; 11/80 patients (14%) of the CB240 group experienced a PN injury, three in a persistent form (p = .10). A LET <15°C was recorded in 3/80 patients (4%) in the CB120 group and in 16/80 patients (20%) in the CB240 group (p < .01). Composite rate of energy-related safety events (LET <15°C and PN injury) was significantly lower in the CB120 (34% vs. 9%, p < .01). CONCLUSIONS: Safety of second generation CB PVI can be increased using a double 120 s freeze protocol.
No takes yet. Share an insight, caveat, or question.
Bianchini et al. (2021) conducted a cohort in Symptomatic atrial fibrillation (n=160). Double 120 seconds freeze protocol vs. Single 240 seconds freeze protocol was evaluated on Composite rate of energy-related safety events (luminal esophageal temperature <15°C and phrenic nerve injury) (p=<0.01). The double 120 seconds freeze protocol reduced the composite rate of energy-related safety events from 34% to 9% compared to the single 240 seconds freeze protocol.
Synapse has enriched 10 related papers. Consider them for comparative context: