Key result
Microelectrode array mapping shows 4-aminopyridine reduces sinoatrial node firing rate by ~110 bpm.
Why the study?
Traditional methods to assess intrinsic cardiac pacemaker function by eliminating autonomic influence are technically challenging and difficult to perform.
This paper introduces a novel, efficient microelectrode array methodology for recording intrinsic sinoatrial node firing rates in mice, facilitating the study of cardiac pacemaking defects.
Answers are grounded in this paper and cite their sources.
New MEA method streamlines mouse SAN recordings; leaves open translation to human pacemaker disorders.
The sinoatrial node (SAN), located in the right atrium, contains the pacemaker cells of the heart, and dysfunction of this region can cause tachycardia or bradycardia. Reliable identification of cardiac pacemaking defects requires the measurement of intrinsic heart rates by largely preventing the influence of the autonomic nervous system, which can mask rate deficits. Traditional methods to analyze intrinsic cardiac pacemaker function include drug-induced autonomic blockade to measure in vivo heart rates, isolated heart recordings to measure intrinsic heart rates, and sinoatrial strip or single-cell patch-clamp recordings of sinoatrial pacemaker cells to measure spontaneous action potential firing rates. However, these more traditional techniques can be technically challenging and difficult to perform. Here, we present a new methodology to measure intrinsic cardiac firing rate by performing microelectrode array (MEA) recordings of whole-mount sinoatrial node preparations from mice. MEAs are composed of multiple microelectrodes arranged in a grid-like pattern for recording in vitro extracellular field potentials. The method described herein has the combined advantage of being relatively faster, simpler, and more precise than previous approaches for recording intrinsic heart rates, while also allowing easy pharmacological interrogation.
No takes yet. Share an insight, caveat, or question.
Kumar et al. (2021) studied Sinoatrial node function. Microelectrode array (MEA) recording vs. Traditional methods (in vivo autonomic blockade, isolated heart, single-cell patch-clamp) was evaluated on Intrinsic sinoatrial node firing rate (beat frequency). Microelectrode array recording of whole-mount sinoatrial node preparations provides an efficient methodology to measure intrinsic cardiac firing rates, successfully demonstrating that 1 mM 4-aminopyridine decreased beat frequency from 320 bpm to 210 bpm.
Synapse has enriched 10 related papers. Consider them for comparative context: