Key result
Simultaneous dual transseptal conduction with fast and slow properties across an injured septum caused a unique QRS morphology in bundle branch reentrant ventricular tachycardia.
Case Report (n=1)
This case report describes a unique mechanism of bundle branch reentrant ventricular tachycardia involving simultaneous dual transseptal conduction through 'fast' and 'slow' pathways.
Answers are grounded in this paper and cite their sources.
Recognize dual transseptal conduction in BBRVT with atypical QRS; extends mechanistic descriptions but leaves open prevalence and impact.
Dual Transseptal Conduction in Bundle Branch Reentry. We report the case of a patient with bundle branch reentrant ventricular tachycardia having two distinct components of the QRS complex due to simultaneous dual transseptal conduction. The macroreentrant circuit consisted of anterograde conduction down the left bundle branch and retrograde conduction up the right bundle branch. Extensively injured myocardium in the interventricular septum isolated the two separate transseptal passages, which exhibited a “fast” and “slow” conduction property, respectively. The QRS configuration resulted from a wavefront propagating from the left bundle branch via “fast” transseptal conduction, followed by another more delayed wavefront propagating via “slow” transseptal conduction, which played an important role in determining this unique QRS morphology.
No takes yet. Share an insight, caveat, or question.
Kaneko et al. (2000) conducted a case report in Bundle branch reentrant ventricular tachycardia (n=1). Simultaneous dual transseptal conduction was evaluated on QRS configuration and macroreentrant circuit characteristics. Simultaneous dual transseptal conduction with fast and slow properties across an injured septum caused a unique QRS morphology in bundle branch reentrant ventricular tachycardia.