Key result
Inactivated epimyocardial pacing leads in Fontan patients had higher initial pacing thresholds compared to leads that remained active.
Why the study?
Cardiac pacing can be challenging after a Fontan operation, and limited data exist regarding strategies to plan epimyocardial systems while minimizing surgical procedures.
Do epimyocardial leads demonstrate stable parameters and low revision rates in patients with a Fontan circulation?
Observational (n=47)
Do epimyocardial leads demonstrate stable parameters and low revision rates in patients with a Fontan circulation?
Answers are grounded in this paper and cite their sources.
Epimyocardial leads in Fontan patients show good long-term stability when implanted with low initial pacing thresholds, and the use of reserve leads or resynchronization systems may help reduce future surgical revisions.
BACKGROUND: Cardiac pacing can be challenging after a Fontan operation, and limited data exist regarding strategies to plan these epimyocardial systems while minimizing the number of surgical procedures. METHODS: A retrospective review of all our 47 patients (mean age 18 years, standard deviation 9 years) with a Fontan palliation who received an epimyocardial cardiac implantable electronic device (CIED) between 2002 and 2020 with regard to the stability of the epimyocardial lead parameters and the incidence of system revisions. RESULTS: Over the last 18 years, 84 implantations or revisions of the epimyocardial CIED in 47 Fontan patients were performed. Mean age at time of the first implantation was 9.4 (range 0.28-29.3) years. Follow-up period ranges from 0.11 to 18.2 (mean 7.7, standard deviation 4.2) years. A total of 123 pacing leads were implanted of which 99 are still active. From 2010 triple lead cardiac resynchronization devices were used in 17 patients to better cope with lead problems. The initial pacing threshold of the leads inactivated during this study period proved significantly higher (mean 1.66 V) than in the "all leads" group (mean 1.27 V, p = .0005) or the group of the still active leads (mean 1.17 V, p = .00004). CONCLUSIONS: When implanted with a low pacing threshold, the bipolar epimyocardial electrodes show stable and good long-term results in young patients with a Fontan circulation. Resynchronization pacing systems and the prospective implantation of reserve leads may help to reduce the rate of resternotomies and provide a flexible concept to deal with lead failure.
No takes yet. Share an insight, caveat, or question.
Zartner et al. (2021) conducted an observational in Single ventricle circulation / Fontan palliation (n=47). Epimyocardial cardiac implantable electronic device (CIED) vs. Active leads was evaluated on Initial pacing threshold (p=0.00004). Inactivated epimyocardial pacing leads in Fontan patients had higher initial pacing thresholds compared to leads that remained active.
Synapse has enriched 10 related papers. Consider them for comparative context: