Key result
Echocardiographic calcium scoring accurately discriminated coronary artery disease with an AUC of 0.84, while advanced ECG and NTproBNP accurately identified left ventricular dysfunction.
Why the study?
Cardiovascular disease screening has not been widely advocated due to cost and is reserved for high-risk or symptomatic patients, prompting evaluation of promising low-cost screening methods.
Does a multi-omic screening approach accurately detect cardiac disease in patients?
Observational (n=78)
Does a multi-omic screening approach accurately detect cardiac disease in patients?
A multi-omic screening approach combining advanced ECG, echocardiography, biomarkers, and metabolomics demonstrates high accuracy for detecting LV dysfunction, CAD, and LVH at relatively low cost.
Answers are grounded in this paper and cite their sources.
May support low-cost screening for CAD and LV dysfunction; hypothesis-generating and requires prospective validation.
Introduction Screening patients for cardiovascular disease has not been widely advocated due to cost implications and is reserved for high risk or symptomatic patients. We undertook an exploratory study to evaluate the promising low-cost methods for screening, including genetic risk scoring (GRS), advanced ECG (A-ECG), echocardiography and metabolomics. Methods 78 patients underwent advanced 5-min ECG and echocardiography, including global longitudinal strain (GLS), and echocardiographic calcium scoring (eCS). A GRS of 27 SNPs (GRS27) related to coronary disease and 3 SNPs for atrial fibrillation was used, as well as hs-troponin (Abbott, Singulex, Roche), NTproBNP (Roche) testing and targeted plasma metabolomics using GC-MS. Results were correlated with the presence of coronary artery disease (CAD) (CT coronary angiography (CTCA)), measures of left ventricular hypertrophy (LVH) (echocardiography and CTCA), and LV systolic dysfunction (LVSD) (echocardiography). Results LV dysfunction was accurately identified by using either A-ECG (AUC 0.97, 0.89 to 0.99) or NTproBNP. eCS demonstrated accurate discrimination of CAD (AUC 0.84, 95% CI 0.72 to 0.92, p < 0.0001. Troponin I (Abbott/Singulex) had the highest sensitivity and accuracy for the detection of LVH measured by either CT or echocardiography (AUC 0.85, 95% CI 0.73 to 0.92), however specificity was reduced by the presence of LV systolic dysfunction. Metabolomics and A-ECG identified underlying abnormal mechanisms related to both LVH (glycine metabolism) and LV dysfunction, (Citric Acid cycle). Metabolomics provided incidental utility by identifying metformin adherence and nutritional biomarkers. Conclusion A multi-omic approach to screening can be achieved at relatively low cost, and high accuracy, but will need to be evaluated in larger populations to prove its utility.
No takes yet. Share an insight, caveat, or question.
Gladding et al. (2021) conducted an observational in Cardiac disease (Coronary artery disease, Left ventricular dysfunction, Left ventricular hypertrophy) (n=78). Multi-omic screening (A-ECG, echocardiographic calcium scoring, biomarkers, metabolomics) vs. Standard clinical risk scores and imaging was evaluated on Discrimination of coronary artery disease (CAD) using echocardiographic calcium scoring (eCS) (AUC 0.84, 95% CI 0.72 to 0.92, p=<0.0001). Echocardiographic calcium scoring accurately discriminated coronary artery disease with an AUC of 0.84, while advanced ECG and NTproBNP accurately identified left ventricular dysfunction.
Synapse has enriched 10 related papers. Consider them for comparative context: