Key result
Magnetic resonance imaging can be safely performed in patients with either conditional or nonconditional cardiac implanted electronic devices when appropriate institutional policies and monitoring are used.
Why the study?
Can MRI be safely performed in patients with cardiac implanted electronic devices (CIEDs)?
Can MRI be safely performed in patients with cardiac implanted electronic devices (CIEDs)?
MRI can be safely performed in patients with both MR-conditional and nonconditional CIEDs provided appropriate institutional safety protocols and cross-departmental collaborations are in place.
Supports MRI in CIED patients with institutional protocols; leaves open need for prospective validation and standardized guidelines.
Cardiac implanted electronic devices (CIEDs) have historically been regarded as a contraindication for performing magnetic resonance imaging (MRI), limiting the availability of this exam for large numbers of patients who may have otherwise benefited from the unique diagnostic capabilities of MRI. Interactions between CIEDs and the magnetic field associated with MRI systems have been documented, and include potential effects on CIED function, lead heating, and force/torque on the generator. Several device manufacturers have developed "MR-Conditional" CIEDs with specific hardware and software design changes to optimize the device for the MR environment. However, a substantial body of evidence has been accumulating that suggests that MRI may be safely performed in patients with either conditional or nonconditional CIEDs. Institutional policies and procedures, including preexam screening and assessment by skilled electrophysiology personnel and intraexam monitoring, allow MRI to be safely performed in CIED patients, as evidenced by at least two, large multicenter prospective studies and multiple smaller, single-institution studies. Cross-departmental collaboration and a robust safety infrastructure at sites that perform MRI should allow for the safe imaging of CIED patients who have a clinical indication for the study, regardless of the conditionality status of the device. LEVEL OF EVIDENCE: 5 Technical Efficacy: Stage 5 J. Magn. Reson. Imaging 2018;47:595-603.
No takes yet. Share an insight, caveat, or question.
Kalb et al. (2017) conducted a review in Patients with cardiac implanted electronic devices (CIEDs). Magnetic resonance imaging (MRI) was evaluated. Magnetic resonance imaging can be safely performed in patients with either conditional or nonconditional cardiac implanted electronic devices when appropriate institutional policies and monitoring are used.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: