Answers are grounded in this paper and cite their sources.
Randomized trial evaluates ergonomic comfort and clinical outcomes in women undergoing laparoscopic surgery, indicating positive staff experiences.
OBJECTIVE: To evaluate short-term clinical outcomes, surgeon-reported fatigue, and staff user experience associated with a multifunctional operative support arm in reproductive laparoscopic surgery. DESIGN: Single-center, parallel-group randomized controlled trial. SETTING: Tertiary university-affiliated reproductive medicine center. PATIENTS: One hundred women aged 25-40 years undergoing laparoscopic surgery for stage I pelvic endometriosis, hydrosalpinx, or benign ovarian cysts. INTERVENTIONS: Participants were randomized to surgery using the multifunctional operative support arm or a conventional passive support condition. MAIN OUTCOME MEASURES: The primary outcome was surgeon-reported fatigue assessed using a 0-10 visual analog scale. Secondary outcomes included staff satisfaction and device-related comfort. Clinical outcomes included operative duration, postoperative infection, length of stay, anti-Müllerian hormone, and antral follicle count. Ventilation, temperature control, and comfort scores were also higher, although satisfaction differences were small. CONCLUSION: The device improved staff-reported ergonomic comfort without adverse short-term clinical effects, but confirmation with objective measures is needed.
No takes yet. Share an insight, caveat, or question.
Mao et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: