Key result
3D interpolated MRI datasets derived from multiple 2D FLASH acquisitions enabled confident atrial fibrillation cardiac radioablation target delineation (average score 4.9/5), whereas 3D free-breathing acquisitions did not.
Why the study?
Visibility of AF cardiac radioablation targets on MRI requires exploration, and MRI sequence and parameter optimization had not yet been performed for this application.
Do optimized MRI sequences improve the visualization and delineation of cardiac radioablation targets in patients with atrial fibrillation and healthy volunteers?
Observational (n=25)
No
Do optimized MRI sequences improve the visualization and delineation of cardiac radioablation targets in patients with atrial fibrillation and healthy volunteers?
Stacks of 2D breath-hold ECG-gated MRI acquisitions interpolated to 3D datasets provide sufficient image quality for confident delineation of atrial fibrillation cardiac radioablation targets, supporting the feasibility of MRI-guided treatments.
Supports feasibility of interpolated 2D FLASH MRI for AF radioablation planning; leaves open prospective validation before clinical adoption.
Magnetic resonance imaging (MRI) guided cardiac radioablation (CR) for atrial fibrillation (AF) is a promising treatment concept. However, the visibility of AF CR targets on MRI acquisitions requires further exploration and MRI sequence and parameter optimization has not yet been performed for this application. This pilot study explores the feasibility of MRI-guided tracking of AF CR targets by evaluating AF CR target visualization on human participants using a selection of 3D and 2D MRI sequences.MRI datasets were acquired in healthy and AF participants using a range of MRI sequences and parameters. MRI acquisition categories included 3D free-breathing acquisitions ( 3D acq ), 2D breath-hold ECG-gated acquisitions ( 2D ECG-gated ), stacks of 2D breath-hold ECG-gated acquisitions which were retrospectively interpolated to 3D datasets ( 3D interp ), and 2D breath-hold ungated acquisitions ( 2D real-time ). The ease of target delineation and the presence of artifacts were qualitatively analyzed. Image quality was quantitatively analyzed using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and non-uniformity. Confident 3D target delineation was achievable on all 3D interp datasets but was not possible on any of the 3D acq datasets. Fewer artifacts and significantly better SNR, CNR and non-uniformity metrics were observed with 3D interp compared to 3D acq . 2D real-time datasets had slightly lower SNR and CNR than 2D ECG-gated and 3D interp n datasets. AF CR target visualization on MRI was qualitatively and quantitatively evaluated. The study findings indicate that AF CR target visualization is achievable despite the imaging challenges associated with these targets, warranting further investigation into MRI-guided AF CR treatments.
No takes yet. Share an insight, caveat, or question.
Lydiard et al. (2022) conducted an observational in Atrial Fibrillation (n=25). 3D interpolated MRI datasets (3Dinterp) vs. 3D free-breathing MRI acquisitions (3Dacq) was evaluated on Qualitative ease of 3D target delineation (score 1-5) (p=≤0.001). 3D interpolated MRI datasets derived from multiple 2D FLASH acquisitions enabled confident atrial fibrillation cardiac radioablation target delineation (average score 4.9/5), whereas 3D free-breathing acquisitions did not.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: