Key result
Cardiac radioablation target motion was 4-5 mm due to cardiac contraction and 13-14 mm due to respiration, highlighting the need for personalized motion compensation techniques.
Why the study?
Safe delivery of cardiac radioablation for AF is challenged by multi-direction target motion, rate variability, and proximity to critical structures, necessitating characterization to guide optimal treatment technique.
Observational (n=15)
Cardiac radioablation for atrial fibrillation requires personalized motion compensation techniques due to significant target motion from cardiac contraction and respiration, as well as proximity to the esophagus.
Answers are grounded in this paper and cite their sources.
Target motion and esophageal contact necessitate caution in radioablation planning; leaves open optimal compensation methods for AF.
Purpose The safe delivery of cardiac radioablation (CR) for atrial fibrillation (AF) is challenged by multi‐direction target motion, cardiac rate variability, target proximity to critical structures, and the importance of complete target dose coverage for therapeutic benefit. Careful selection of appropriate treatment procedures is therefore essential. This work characterizes AF cardiac radioablation target motion and target proximity to surrounding structures in both healthy and AF participants to guide optimal treatment technique and technology choice. Methods Ten healthy participants and five participants with AF underwent MRI acquisition. Multi‐slice, cardiac‐gated, breath‐hold cines were acquired and interpolated to create three‐dimensional images for 18–30 cardiac phases. Treatment targets at the left and right pulmonary vein ostia (CTV Left and CTV Right respectively) and adjacent cardiac structures were contoured and their displacements throughout the cardiac cycle were assessed. Target proximity to surrounding structures were measured. Free‐breathing real‐time two‐dimensional cine images were also acquired at 4 Hz frequency for between 1‐ and 2‐min duration. The motion of easily identifiable points within the target, diaphragm and sternum was measured to assess respiratory motion. Results Target motion due to cardiac contraction was most prominent in the medial‐lateral direction and of 4–5 mm magnitude. CTV Right displacements were smaller in participants with AF than healthy participants in normal sinus rhythm. Nearby cardiac structures often moved with different magnitudes and motion trajectories. CTV Left and/or CTV Right were in direct contact with the esophagus in 73% of participants. Target motion due to respiration was most prominent in the superior–inferior direction and of 13–14 mm magnitude in both healthy and AF participants. Conclusion AF CR target motion and relative displacement was characterized. The combination of target motion magnitude and relative displacement to critical structures highlights the importance of personalizing motion compensation techniques for effective AF CR treatments.
No takes yet. Share an insight, caveat, or question.
Lydiard et al. (2020) conducted an observational in Atrial fibrillation (n=15). Target motion characterization via MRI vs. Healthy participants was evaluated on Target motion due to cardiac contraction and respiration. Cardiac radioablation target motion was 4-5 mm due to cardiac contraction and 13-14 mm due to respiration, highlighting the need for personalized motion compensation techniques.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: