In a computational model of mitral valve edge-to-edge repair, commissural suturing generated the lowest wall shear stresses and a single vortex ring compared to central or lateral suturing.
Answers are grounded in this paper and cite their sources.
Commissural suturing may minimize shear stress in mitral repair models; leaves open optimal position pending clinical validation.
Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.
No takes yet. Share an insight, caveat, or question.
Du et al. (2014) studied this question.