Key result
Novel computational model evaluates how edge-to-edge repair parameters affect mitral valve function and stress.
A novel computational approach using structural finite element analysis and Bernoulli equations can predict the functional and structural effects of edge-to-edge mitral valve repair.
Answers are grounded in this paper and cite their sources.
Computational modeling of edge-to-edge mitral repair may flag critical suture effects; leaves open clinical translation pending validation.
Edge-to-edge technique is a surgical procedure for the correction of mitral valve leaflets prolapse by suturing the edge of the prolapsed leaflet to the free edge of the opposing one. Suture presence modifies valve mechanical behavior and orifice flow area in the diastolic phase, when the valve opens and blood flows into the ventricle. In the present work, in order to support identification of potentially critical conditions, a computational procedure is described to evaluate the effects of changing suture length and position in combination with valve size and shape. The procedure is based on finite element method analyses applied to a range of different mitral valves, investigating for each configuration the influence of repair on functional parameters, such as mitral valve orifice area and transvalvular pressure gradient, and on structural parameters, such as stress in the leaflets and stitch tension. This kind of prediction would ideally require a coupled fluid-structural analysis, where the interactions between blood flows and mitral apparatus deformation are simultaneously considered. In the present study, however, an alternative approach is proposed, in which results obtained by purely structural finite element analyses are elaborated and interpreted taking into account the Bernoulli type equations available in literature to describe blood flow through mitral orifice. In this way, the effects of each parameter in terms of orifice flow area, suture loads, and leaflets stresses can be expressed as functions of atrioventricular pressure gradient and then correlated to blood flow rate. Results obtained by using this procedure for different configurations are finally discussed.
No takes yet. Share an insight, caveat, or question.
Andrea Avanzini (2008) studied Mitral valve leaflet prolapse. Edge-to-edge repair (computational modeling) was evaluated on Mitral valve orifice area, transvalvular pressure gradient, stress in leaflets, and stitch tension. A computational procedure using structural finite element analyses and Bernoulli equations was developed to evaluate the effects of edge-to-edge repair parameters on mitral valve function and stress.
Synapse has enriched 10 related papers. Consider them for comparative context: