Contact force guidance during atrial fibrillation ablation did not improve freedom from AF in randomized trials (RR 1.03; 95% CI 0.95-1.11), despite observational data showing dramatic improvement.
Meta-Analysis (n=9,822)
Does contact force (CF) guided ablation improve freedom from AF and reduce complications compared to non CF-guided ablation in patients undergoing atrial fibrillation ablation?
Contact force sensing during AF ablation does not improve clinical efficacy or safety outcomes when analyzing randomized trial data, highlighting discrepancies with observational studies.
Relative Risk: 1.03 (95% CI 0.95–1.11)
Despite widespread adoption of contact force (CF) sensing technology in atrial fibrillation (AF) ablation, randomized data suggests lack of improvement in clinical outcomes. We aimed to assess the safety and efficacy of CF-guided vs. non CF-guided AF ablation.Electronic databases were searched for randomized controlled trials (RCTs) and controlled observational studies (OS) comparing outcomes of AF ablation performed with vs. without CF guidance. The primary efficacy endpoint was freedom from AF at follow-up. The primary safety endpoint was major peri-procedural complications. Secondary endpoints included procedural, fluoroscopy, and ablation duration. Subgroup analyses were performed by AF type and study design. Nine RCTs (n = 903) and 26 OS (n = 8919) were included. Overall, CF guidance was associated with improved freedom from AF relative risk (RR) 1.10; 95% confidence interval (CI) 1.02-1.18, and reduced total procedure duration mean difference (MD) 15.33 min; 95% CI 6.98-23.68, ablation duration (MD 3.07 min; 95% CI 0.29-5.84), and fluoroscopy duration (MD 5.72 min; 95% CI 2.51-8.92). When restricted to RCTs however, CF guidance neither improved freedom from AF (RR 1.03; 95% CI 0.95-1.11), independent of AF type, nor did it reduce procedural, fluoroscopy, or ablation duration. Contact force guidance did not reduce the incidence of major peri-procedural complications (RR 0.89; 95% CI 0.64-1.24).Meta-analysis of randomized data demonstrated that CF guidance does not improve the safety or efficacy of AF ablation, despite initial observational data showing dramatic improvement. Rigorous evaluation in randomized trials is needed before widespread adoption of new technologies.
Virk et al. (Thu,) conducted a meta-analysis in Atrial fibrillation (n=9,822). Contact force (CF) guidance vs. Non CF-guided AF ablation was evaluated on Freedom from AF at follow-up (RR 1.03, 95% CI 0.95-1.11). Contact force guidance during atrial fibrillation ablation did not improve freedom from AF in randomized trials (RR 1.03; 95% CI 0.95-1.11), despite observational data showing dramatic improvement.