A well-characterised sample of silicon tunable-barrier electron pump has been operated at a frequency of 2 GHz using a custom drive waveform, generating a pump current of 320 pA. Precision measurements of the current were made as a function of pump control parameters, using a blind protocol, over a 7 week campaign. The combined standard uncertainty for each ∼ 10 h measurement was in the range 0.16 − 0.18 parts per million (ppm). The pump current exhibits a plateau along the exit gate voltage flat to approximately 0.15 ppm, but offset from ef by 0.2 ppm. This offset may be a sign of errors in the current traceability chain, indicating a limit to the accuracy of small current scaling using existing methods based on cryogenic current comparators.
No takes yet. Share an insight, caveat, or question.
Giblin et al. (2023) studied this question.
Synapse has enriched 5 related papers. Consider them for comparative context: