Why the study?
What are the predictors of mortality in patients undergoing pacemaker and defibrillator lead extraction?
What are the predictors of mortality in patients undergoing pacemaker and defibrillator lead extraction?
Preprocedural C-reactive protein is a predictor of acute in-hospital mortality in patients undergoing cardiac device lead extraction, identifying a subgroup with systemic sepsis at high risk.
Answers are grounded in this paper and cite their sources.
May support CRP-based risk stratification before lead extraction; hypothesis-generating and requires prospective validation.
BACKGROUND: Extraction of cardiac implantable electric devices is an accepted procedure when systems become infected or malfunction. However, there is an associated morbidity and mortality. We report our 5-year experience and identify predictors of mortality, and long-term follow-up. METHODS: We analyzed extraction data from January 2003 to November 2007. Extraction methods used were: locking stylets, telescoping sheaths +/- laser, and femoral work stations. RESULTS: One hundred and eighty-three cases were referred, aged 65 +/- 16 years (range 28-83); 76% were males. Mean implant time was 75 months (range 4-312 months) and indications were: pocket infection (48%), nonfunctioning lead (22%), erosion through skin (18%), endocarditis/septicemia (11%), bilateral superior vena cava thrombosis (0.5%), and painful lead (0.5%). The number of leads extracted were 369, with complete removal in 90.7% and partial in 7.6%. There were no intraoperative deaths but five (2.7%) died within the same admission as their extraction from overwhelming sepsis. Twelve deaths (6.6%) occurred during an average follow-up of 965 days (range 40-1670). Multivariate logistic regression demonstrated that C-reactive protein preprocedure was predictive of acute in-hospital mortality. CONCLUSIONS: Intravascular lead extraction is a safe and efficient method of removing leads. However, there is a subgroup of patients with systemic sepsis with raised inflammatory markers who are at high risk of in-hospital mortality. Long-term follow-up demonstrates mortality which is a marker of the underlying etiology for device implantation, with heart failure patients particularly at risk.
No takes yet. Share an insight, caveat, or question.
Hamid et al. (2009) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: