Answers are grounded in this paper and cite their sources.
System integration of an online structural health monitoring module was accomplished by coupling commercially available microelectro-mechanical system sensors and a wireless telemetry unit with damage detection firmware. To showcase the capabilities of the integrated monitoring module, a bolted frame structure was constructed, and the preload in one of the bolted joints was controlled by a piezoelectric stack actuator to simulate gradual deterioration of a bolted connection. Two separate damage detection algorithms were used to classify a joint as damaged or undamaged. First, a statistical process control algorithm was used to monitor the correlation of vibration data from two accelerometers mounted across a joint. Changes in correlation were used to detect damage to the joint. For each joint, data were processed locally on a microprocessor integrated with the wireless module, and the diagnosis result was remotely transmitted to the base monitoring station. Second, a more sophisticated damage detection algorithm combining time series analysis and statistical hypothesis testing was employed using a conventional wired data acquisition system to classify a joint on the demonstration structure as damaged or undamaged.
No takes yet. Share an insight, caveat, or question.
Tanner et al. (2003) studied this question.