Investigates image quality and motion artefacts in low dose chest CT, suggesting benefits of ultra-fast scanning.
OBJECTIVES: The main objective of this study was to investigate how ultra-fast CT scanning influences cardiac pulsation artefacts and image quality in low dose chest CT, clinically and in a non-moving 3D resolution phantom. METHODS: 30 patients underwent two non-contrast chest CT examinations within 6 months using one ultra-fast and one standard speed protocol. Three radiologists scored general image quality and motion artefacts (ascending aorta, superior aortic recess, left ventricle, lung tissue) using a 4-point Likert scale. Lung parenchyma, pulmonary fissures, segmental bronchi, pleuromediastinal border, carina and pulmonary vessels were compared between ultra-fast and standard speed scans. Volumetric resolution was measured with an image quality phantom containing a 3D resolution wave module to assess the non-motion resolution on both protocols. CONCLUSION: In this study, ultra-fast scans reduce motion artefacts and increase image quality in low dose non-contrast chest CT when compared to standard speed scans, despite a possible slight degradation in resolution in non-moving objects.
No takes yet. Share an insight, caveat, or question.
Tormodsrud et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: