Key result
An automated blood pressure system (Critikon Model 1165) correlated highly with manual measurements for systolic blood pressure during cycle ergometer stress testing in children.
Why the study?
Does an automated blood pressure measurement system provide accurate systolic blood pressure readings compared to manual measurement in children undergoing cycle ergometer stress testing?
Observational (n=121)
Single-blind
Does an automated blood pressure measurement system provide accurate systolic blood pressure readings compared to manual measurement in children undergoing cycle ergometer stress testing?
An automated blood pressure measurement system provides highly correlated readings to manual measurement during pediatric exercise stress testing, potentially eliminating intraobserver variation and freeing clinician attention.
Answers are grounded in this paper and cite their sources.
May support automated BP monitoring in pediatric ergometer testing; leaves open prospective validation before routine use.
The measurement of systolic and diastolic blood pressure during exercise is often difficult to perform due to patient motion and environmental noise. We evaluated an automated system of blood pressure determination in 121 children undergoing cycle ergometer stress testing. The system (Critikon Model 1165) utilized acoustic transduction, with electrocardiogram gating and microprocessor signal filtering. One observer measured the blood pressure values from the same arm as the automated system; this observer was blinded to the readout of the system. The correlation coefficients for systolic blood pressure at rest, during exercise, and during recovery were all greater than 0.91, and improved with the use of a stethophone adapter. This system can eliminate intraobserver variation as well as the necessity for the technician or physician to direct attention away from the electrocardiogram and patient during stress testing.
No takes yet. Share an insight, caveat, or question.
Alpert et al. (1982) conducted an observational in Children undergoing cycle ergometer stress testing (n=121). Automated blood pressure determination system (Critikon Model 1165) vs. Manual blood pressure measurement was evaluated on Correlation coefficients for systolic blood pressure at rest, during exercise, and during recovery (r > 0.91). An automated blood pressure system (Critikon Model 1165) correlated highly with manual measurements for systolic blood pressure during cycle ergometer stress testing in children.