Key result
In this first-in-human study, the BIOVALVE system demonstrated feasibility and safety with a 30-day early safety composite event rate of 15.4% and no deaths or strokes.
The novel BIOVALVE self-expanding transcatheter heart valve demonstrated initial feasibility and encouraging short-term safety in high-risk patients with severe aortic stenosis.
Should not yet change TAVR practice; leaves open BIOVALVE's role pending larger prospective trials.
AIMS: Transcatheter aortic valve therapy has become an established procedure for patients at high risk for surgical valve replacement. The BIOVALVE-I study aims to assess the safety and performance of a novel self-expanding transcatheter heart valve. METHODS AND RESULTS: In this prospective, single-centre, first-in-human study, 13 patients with severe aortic stenosis suitable for transfemoral transcatheter aortic valve implantation were enrolled. Mean logistic EuroSCORE was 14.4±3.7% and mean STS PROM score was 4.3±1.6%. The primary endpoint, 30-day early safety composite per VARC-2, was observed in two patients (15.4%, one life-threatening bleeding and one valve-in-valve procedure). The implant was aborted in two patients due to unsuitable aortic anatomy. Overall, device success was obtained in nine patients (69.2%, two aborted implants, one valve-in-valve procedure and one patient with moderate aortic regurgitation). As determined by an independent core laboratory, all but one patient had less than moderate total aortic regurgitation at 30-day follow-up, mean aortic gradient was 6.7±2.3 mmHg and effective orifice area 1.8±0.3 cm. Pacemakers were implanted in three patients (23.1%), and no death, stroke, myocardial infarction or acute kidney failure was observed. CONCLUSIONS: In this first-in-human study, the feasibility of implantation of the BIOVALVE system and its re-sheathing functionality was demonstrated, and short-term safety data were encouraging. Larger studies are required to confirm the performance of the device.
No takes yet. Share an insight, caveat, or question.
Treede et al. (2015) studied Severe symptomatic aortic valve stenosis (n=13). BIOVALVE transcatheter aortic valve system was evaluated on 30-day early safety composite per VARC-2. In this first-in-human study, the BIOVALVE system demonstrated feasibility and safety with a 30-day early safety composite event rate of 15.4% and no deaths or strokes.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: