Key result
Transfemoral TAVR achieves 100% technical success in pure native aortic regurgitation.
Why the study?
Achieving stable anchoring and effective sealing remains the principal limitation of TAVR in patients with pure native aortic regurgitation.
Does transfemoral TAVR with a short-frame, fully recapturable self-expanding valve achieve procedural technical success in patients with symptomatic pure native aortic regurgitation?
Observational (n=13)
No
Does transfemoral TAVR with a short-frame, fully recapturable self-expanding valve achieve procedural technical success in patients with symptomatic pure native aortic regurgitation?
Transfemoral TAVR using a short-frame, fully recapturable self-expanding valve system demonstrated 100% technical success and favorable short-term safety in selected patients with pure native aortic regurgitation.
BACKGROUND Achieving stable anchoring and effective sealing remains the principal limitation of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (PNAR). A short-frame, fully recapturable self-expanding valve may expand the procedural margin by enabling iterative repositioning and implantation depth optimisation in non-calcified anatomy. METHODS We analysed 13 consecutive patients with symptomatic moderate-to-severe or severe PNAR who underwent transfemoral TAVR with the ScienCrown® (Lepu Medical, Beijing, China) system. The primary endpoint was technical success at exit from the procedure room according to VARC-3 criteria. Secondary endpoints included device success and early safety at 30 days. RESULTS Technical success was achieved in all patients (13/13, 100%), and device success at 30 days was also achieved in all patients (13/13, 100%). The 30-day early safety endpoint was met in 12 patients (92.3%). The mean prosthesis size was 27.62 ± 1.26 mm, with a mean prosthesis diameter oversizing relative to the average annular diameter of 12.90 ± 3.54%; no balloon predilatation was performed. The mean number of deployment attempts was 1.62 ± 0.77. All procedures were completed without valve embolisation/migration, coronary obstruction, second-valve implantation, or emergency surgery. One patient (7.69%) developed complete atrioventricular block on postoperative day 3 and underwent permanent pacemaker implantation; no additional pacemaker implantations occurred through 30 days. Predischarge diffusion-weighted magnetic resonance imaging demonstrated no new acute cerebral infarction. At 30 days, there were no deaths, strokes or transient ischaemic attacks, myocardial infarction, life-threatening/major bleeding, major vascular complications, endocarditis, or valve-related reinterventions. Mean transvalvular gradients were 7.67 ± 5.20 mmHg, and all patients had improved or stable NYHA functional class with no moderate or severe residual aortic regurgitation. CONCLUSIONS In this exploratory single-centre series, transfemoral TAVR using a short-frame, fully recapturable self-expanding valve achieved 100% technical success and favourable early safety and haemodynamic performance in selected patients with PNAR. Prospective multicentre studies with longer follow-up and appropriate comparator groups are warranted.
No takes yet. Share an insight, caveat, or question.
Yan et al. (2026) conducted an observational in Pure native aortic regurgitation (PNAR) (n=13). Transfemoral TAVR using ScienCrown system (short-frame, fully recapturable self-expanding valve) was evaluated on Technical success at exit from the procedure room according to VARC-3 criteria. Transfemoral TAVR with a short-frame, self-expanding valve achieved 100% technical success and 92.3% early safety at 30 days in patients with pure native aortic regurgitation.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: