Key result
High relative spatial intima-media thickness inhomogeneity (>2%) of the common carotid artery is associated with a 5% greater degree of internal carotid artery stenosis compared to low inhomogeneity.
Why the study?
Is high relative spatial intima-media thickness (IMT) inhomogeneity of the common carotid artery associated with a larger degree of stenosis in the internal carotid artery in patients with recent ischemic stroke or TIA?
Observational (n=182)
Yes
Is high relative spatial intima-media thickness (IMT) inhomogeneity of the common carotid artery associated with a larger degree of stenosis in the internal carotid artery in patients with recent ischemic stroke or TIA?
High relative common carotid artery IMT inhomogeneity is associated with a greater degree of internal carotid artery stenosis, suggesting it may serve as an indicator of atherosclerotic disease burden.
Purpose Inhomogeneity of arterial wall thickness may be indicative of distal plaques. This study investigates the intra-subject association between relative spatial intima-media thickness (IMT) inhomogeneity of the common carotid artery (CCA) and the degree of stenosis of plaques in the internal carotid artery (ICA). Materials and Methods We included 240 patients with a recent ischemic stroke or transient ischemic attack and mild-to-moderate stenosis in the ipsilateral ICA. IMT inhomogeneity was extracted from B-mode ultrasound recordings. The degree of ICA stenosis was assessed on CT angiography according to the European Carotid Surgery Trial method. Patients were divided into groups with a low (≤ 2 %) and a high (> 2 %) IMT inhomogeneity scaled with respect to the local end-diastolic diameter. Results 182 patients had suitable CT and ultrasound measurements. Relative CCA-IMT inhomogeneity was similar for the symptomatic and asymptomatic side (difference: 0.02 %, p = 0.85). High relative IMT inhomogeneity was associated with a larger IMT (difference: 235 µm, p < 0.001) and larger degree of ICA stenosis (difference: 5 %, p = 0.023) which remained significant (p = 0.016) after adjustment for common risk factors. Conclusion Regardless of common risk factors, high relative CCA-IMT inhomogeneity is associated with a greater degree of ICA stenosis and is therefore indicative of atherosclerotic disease. The predictive value of CCA-IMT inhomogeneity for plaque progression and recurrence of cerebrovascular symptoms will be determined in the follow-up phase of PARISK.
No takes yet. Share an insight, caveat, or question.
Steinbuch et al. (2016) conducted an observational in Ischemic stroke or transient ischemic attack (n=182). High relative spatial intima-media thickness (IMT) inhomogeneity (> 2%) vs. Low relative IMT inhomogeneity (≤ 2%) was evaluated on Degree of internal carotid artery (ICA) stenosis (difference: 5%, p=0.023). High relative spatial intima-media thickness inhomogeneity (>2%) of the common carotid artery is associated with a 5% greater degree of internal carotid artery stenosis compared to low inhomogeneity.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: