Key result
Study establishes birth weight-adjusted echocardiographic nomograms and Z-scores in healthy term Indian neonates.
Why the study?
Western echocardiographic nomograms may not be appropriate for Indian neonates, and currently available Indian pediatric nomograms lack or underrepresent neonates, making them unreliable standards.
Cross-Sectional (n=142)
Provides the first specific echocardiographic nomograms and Z-scores for healthy term Indian neonates, improving the reliability of neonatal cardiac dimension interpretations in this population.
May enhance accuracy of neonatal echo interpretation in Indian infants; extends normative data but requires prospective validation.
Background: The availability of nomograms is crucial for the correct interpretation of pediatric and neonatal echocardiograms. Echocardiographic Z-score applications/websites use Western nomograms as reference, which may not be an appropriate standard for gauging Indian neonates. Currently available Indian pediatric nomograms either have not included neonates or have not been specifically designed for neonates. This gross underrepresentation of neonates renders available nomograms unreliable for use as standards for comparison. Objectives: The objective of this study was to collect normative data for the measurement of various cardiac structures using M-Mode and two-dimensional (2D) echo in healthy Indian neonates and to derive Z-scores for each measured parameter. Methods: Echocardiograms were performed on healthy term neonates (within first 5 days of life). Birth weight and length were recorded, and body surface area was calculated using Haycock's formula. Twenty M-mode and 2D-echo parameters were measured (including left ventricular dimensions, atrioventricular valves, and semilunar valves' annuli sizes, pulmonary artery and branches, aortic root, and arch). Results: We studied 142 neonates (73 males) with a mean age of 1.83 ± 1.12 days and mean birth weight of 2.89 ± 0.39 Kg. Regression equations with linear, logarithmic, exponential and square root models were tested to select the best model of fit for the relationship between birth weight and each echocardiographic parameter. Scatter plots and nomogram charts with Z-scores were prepared for each echocardiographic parameter. Conclusions: Our study provides nomograms with Z-scores for term Indian neonates weighing between 2 kg and 4 kg at birth, within first 5 days of life, for a set of echocardiographic parameters that are frequently used in clinical practice. This nomogram has poor predictability for babies at extremes of birth weight. There is a need for further indigenous studies to include neonates at extremes of weight, both term, and preterm.
No takes yet. Share an insight, caveat, or question.
Singh et al. (2023) conducted a cross-sectional in Healthy term neonates (n=142). Echocardiographic assessment was evaluated on Echocardiographic nomograms and Z-scores based on birth weight for 20 cardiac parameters. The study generated birth weight-adjusted echocardiographic nomograms and Z-scores for 20 M-mode and 2D-echo parameters in healthy term Indian neonates.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: