Investigates structural performance enhancement of PCCP using CFRP liners, suggesting improved capacity under pressure.
Prestressed concrete cylinder pipe (PCCP) is a critical structural component widely employed in large‐scale water supply systems. Prestressed steel wire serves as the primary load‐bearing material in PCCP. Over time, as the structure ages, these wires are prone to rupture. Employing carbon fiber‐reinforced polymer (CFRP) liners to rehabilitate PCCP with broken wires offers a trenchless repair solution that significantly enhances the pipe's load‐bearing capacity. However, the mechanical behavior of CFRP‐reinforced PCCP under combined external and internal pressure remains inadequately understood. This study utilizes the finite element method to develop a three‐dimensional model of CFRP‐lined PCCP. The model is validated against experimental data and analytical benchmarks, followed by an in‐depth analysis of how various parameters influence the pipe's structural performance. Results indicate that once external pressure is applied, subsequent reduction in internal pressure does not restore the pipe's original mechanical integrity. Based on the serviceability limit state, reinforcing the pipe with eight layers of CFRP can elevate its external pressure capacity by up to 72.4%.