Why the study?
What is the reproducibility of the ambulatory arterial stiffness index (AASI) derived from 24-h blood pressure recordings in hypertensive patients?
What is the reproducibility of the ambulatory arterial stiffness index (AASI) derived from 24-h blood pressure recordings in hypertensive patients?
The ambulatory arterial stiffness index shows moderate repeatability (coefficients of 50-60%) in hypertensive patients, which is less reproducible than 24-h systolic and diastolic BP.
AASI's moderate repeatability cautions against clinical reliance for serial monitoring; leaves open its research utility pending protocol refinements.
BACKGROUND: We studied the repeatability of the ambulatory arterial stiffness index (AASI), which can be computed from 24-h blood pressure (BP) recordings as unity minus the regression slope of diastolic on systolic BP. METHODS: One hundred and fifty-two hypertensive outpatients recruited in Nijmegen (mean age = 46.2 years; 76.3% with systolic and diastolic hypertension) and 145 patients enrolled in the Systolic Hypertension in Europe (Syst-Eur) trial (71.0 years) underwent 24-h BP monitoring at a median interval of 8 and 31 days, respectively. We used the repeatability coefficient, which is twice the SD of the within-participant differences between repeat recordings, and expressed it as a percentage of four times the SD of the mean of the paired measurements. RESULTS: Mean AASI (crude or derived by time-weighted or robust regression) and 24-h pulse pressure (PP) were similar on repeat recordings in both cohorts. In Nijmegen patients, repeatability coefficients of AASI and PP were approximately 50%. In Syst-Eur trial patients, repeatability coefficient was approximately 60% for AASI and approximately 40% for PP. For comparison, repeatability coefficients for 24-h systolic and diastolic BP were approximately 30%. Differences in AASI between paired recordings were correlated with differences in the goodness of fit (r2) of the AASI regression line as well as with differences in the night-to-day BP ratio. However, in sensitivity analyses stratified for type of hypertension, r2, or dipping status, repeatability coefficients for AASI did not widely depart from 50 to 60% range. CONCLUSION: Estimates of mean AASI were not different between repeat recordings, and repeatability coefficients were within the 50-60% range.
No takes yet. Share an insight, caveat, or question.
Dechering et al. (2008) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: