Key result
ECMO or LVAD during VA ablation is linked to ~266% higher VA recurrence versus Impella.
Why the study?
Data on the efficacy of hemodynamic support for protecting ventricular arrhythmia ablation in high-risk heart failure patients with impaired left ventricular function and its impact on mortality are limited.
Does hemodynamic support improve procedural efficacy, VA-free survival, and mortality in high-risk heart failure patients undergoing ventricular arrhythmia ablation?
Cohort (n=187)
No
Does hemodynamic support improve procedural efficacy, VA-free survival, and mortality in high-risk heart failure patients undergoing ventricular arrhythmia ablation?
In high-risk heart failure patients undergoing ventricular arrhythmia ablation, hemodynamic support is feasible, though ECMO and LVAD use is associated with higher mortality and VA recurrence, likely reflecting greater baseline disease severity.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
May support HS feasibility in high-risk VA ablation; leaves open effects on mortality and VA-free survival.
Background Data on the efficacy of hemodynamic support (HS) for protecting ventricular arrhythmia (VA) ablation in high‐risk heart failure (HF) patients with an impaired left ventricular function and its impact on mortality is limited. Objectives This study aimed to assess procedural efficacy, related complications, VA‐free survival, and mortality of HF patients who underwent protected VA ablation with HS. Methods Data from consecutive HF patients undergoing VA ablation at our center between 2018 and 2024 were analyzed. HS included the treatment with an Impella, an extracorporeal membrane oxygenation (ECMO) or a left ventricular assist device (LVAD). Patients were classified based on their HF status according to current guidelines. Results A total of 187 patients (61.5 ± 10.9 years) were included. 124/187 patients were in advanced HF (66%, 63.5 ± 8.9 years). In 68/187 patients (36%, 60.8 ± 9.8 years), HS was required. Procedural parameter did not differ between the groups except for fluoroscopy times ( p < 0.001). Acute procedural success ( p = 0.670) and major procedure‐related complications ( p = 0.726) were comparable. In‐hospital mortality was higher in patients with HS ( p < 0.001). In advanced HF patients, freedom from VA‐recurrence was lower ( p = 0.016) and mortality higher ( p = 0.009). HS with an ECMO and LVAD, but not with an Impella, was associated with increased VA‐recurrence (hazard ratio [HR] 3.66, confidence Interval [CI] 1.732–7.715, p < 0.001) and mortality (HR 3.95, CI 1.091–14.280, p = 0.036). Conclusion In high‐risk HF patients, VA ablation was feasible with comparable acute success and procedural complication rates. Patients with ECMO or LVAD showed higher in‐hospital mortality and higher VA recurrence compared to Impella‐supported procedures, likely reflecting more advanced disease severity rather than differences in procedural efficacy.
Guckel et al. (2026) conducted a cohort in Heart failure with ventricular arrhythmia (n=187). Hemodynamic support (ECMO or LVAD) vs. Impella support was evaluated on VA-recurrence (HR 3.66, 95% CI 1.732-7.715, p=<0.001). Hemodynamic support with ECMO or LVAD during ventricular arrhythmia ablation was associated with increased VA-recurrence (HR 3.66; 95% CI 1.732-7.715; P<0.001) compared to Impella.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: