Key result
Three cardiac software packages correlate strongly with 2D echo EF, with Myovation Evolution aligning closest.
Why the study?
The study aimed to validate semiquantitative and functional parameters from three cardiac software packages and compare their derived ejection fraction with 2D echocardiography.
Do different cardiac software packages (Emory Cardiac Toolbox, Cardiogam, Myovation Evolution) yield comparable quantitative parameters and ejection fractions compared to 2D echocardiography in patients undergoing myocardial perfusion scintigraphy?
Observational (n=370)
Do different cardiac software packages (Emory Cardiac Toolbox, Cardiogam, Myovation Evolution) yield comparable quantitative parameters and ejection fractions compared to 2D echocardiography in patients undergoing myocardial perfusion scintigraphy?
While three common MPI software packages show strong correlation, notable differences in diagnostic accuracy exist, suggesting the same software should be used for serial patient assessments.
Answers are grounded in this paper and cite their sources.
Software choice may affect MPI EF interpretation; leaves open standardized validation against clinical outcomes.
Myocardial perfusion scintigraphy and 2-dimensional (2D) echocardiography are used for evaluating left ventricular function and ejection fraction (EF). This study aimed to validate the semiquantitative and functional parameters derived from 3 available software packages (Emory Cardiac Toolbox, Cardiogam, and Myovation Evolution) and compare the software-derived EF with that obtained with 2D echocardiography. Methods: This prospective investigation included 370 patients who underwent myocardial perfusion scintigraphy. The participants were stratified into 3 groups on the basis of their left ventricular EF determined by 2D echocardiography. The semiquantitative parameters (summed rest score, summed stress score, summed difference score) and quantitative parameters (defect extent, transient ischemic dilation, EF, end-diastolic volume, end-systolic volume, and stroke volume) derived from each software platform were analyzed. Spearman rank correlation coefficient and Bland–Altman plot analysis were used to assess the relationships among these parameters within the entire cohort and across the 3 subgroups. Results: A strong correlation was found among the parameters across the 3 software programs. Groupwise comparison revealed that group 3 (EF < 50%) exhibited the highest consistency in parameter agreement across software packages. EFs also showed good concordance with 2D echocardiography, particularly in group 3. Among the software packages, Myovation Evolution demonstrated the closest alignment with 2D echocardiography for EF assessment. Conclusion: Although the Emory Cardiac Toolbox, Cardiogam, and Myovation Evolution showed strong correlation among each other and with 2D echocardiography for several parameters, notable differences exist in their diagnostic accuracy and levels of automation. To address these differences, we recommend using the same software for myocardial perfusion quantification method when assessing patients over time or comparing results between them. Published online Jun. 9, 2026.
No takes yet. Share an insight, caveat, or question.
Paul et al. (2026) conducted an observational in Patients undergoing myocardial perfusion scintigraphy (n=370). Cardiac software packages (Emory Cardiac Toolbox, Cardiogam, and Myovation Evolution) vs. 2D echocardiography was evaluated on Correlation of semiquantitative and functional parameters (including ejection fraction) with 2D echocardiography. Three cardiac software packages showed strong correlation with 2D echocardiography for ejection fraction, with Myovation Evolution demonstrating the closest alignment.
Synapse has enriched 10 related papers. Consider them for comparative context: