Key result
Adding 18F-FDG PET/CT to modified Duke criteria improves PVE diagnostic sensitivity to ~97%.
Why the study?
Diagnosing PVE remains challenging because initial echocardiography is normal or inconclusive in almost 30% of cases, reducing the diagnostic accuracy of modified Duke criteria.
Does (18)F-FDG PET/CT improve the diagnostic accuracy for prosthetic valve endocarditis in suspected patients?
Cohort (n=72)
Does (18)F-FDG PET/CT improve the diagnostic accuracy for prosthetic valve endocarditis in suspected patients?
Absolute Event Rate: 97% vs 70%
p-value: p=0.008
The addition of (18)F-FDG PET/CT abnormal uptake as a major criterion significantly improves the sensitivity of the modified Duke criteria for diagnosing prosthetic valve endocarditis.
May enhance early prosthetic valve endocarditis diagnosis; leaves open whether criteria changes affect outcomes.
OBJECTIVES: This study sought to determine the value of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) for diagnosing prosthetic valve endocarditis (PVE). BACKGROUND: The diagnosis of PVE remains challenging. In PVE cases, initial echocardiography is normal or inconclusive in almost 30%, leading to a decreased diagnostic accuracy for the modified Duke criteria. METHODS: We prospectively studied 72 consecutive patients suspected of having PVE. All of the patients were subjected to clinical, microbiological, and echocardiographic evaluation. Cardiac PET/CT was performed at admission. The final diagnosis was defined according to the clinical and/or pathological modified Duke criteria determined during a 3-month follow-up. RESULTS: Thirty-six patients (50%) exhibited abnormal FDG uptake around the site of the prosthetic valve. The sensitivity, specificity, positive predictive value, negative predictive value, and global accuracy were as follows (95% confidence interval): 73% (54% to 87%), 80% (56% to 93%), 85% (64% to 95%), 67% (45% to 84%), and 76% (63% to 86%), respectively. Adding abnormal FDG uptake around the prosthetic valve as a new major criterion significantly increased the sensitivity of the modified Duke criteria at admission (70% [52% to 83%] vs. 97% [83% to 99%], p = 0.008). This result was due to a significant reduction (p < 0.0001) in the number of possible PVE cases from 40 (56%) to 23 (32%). CONCLUSIONS: The use of (18)F-FDG PET/CT was helpful for diagnosing PVE. The results of this study support the addition of abnormal FDG uptake as a novel major criterion for PVE.
No takes yet. Share an insight, caveat, or question.
Saby et al. (2013) conducted a cohort in Prosthetic valve endocarditis (n=72). 18F-FDG PET/CT vs. Standard modified Duke criteria was evaluated on Sensitivity of the modified Duke criteria at admission (p=0.008). Adding abnormal 18F-FDG PET/CT uptake as a major criterion significantly increased the sensitivity of the modified Duke criteria for diagnosing prosthetic valve endocarditis from 70% to 97% (p=0.008).