Key result
Semi-automatic CT software cuts pre-TAVI analysis time by ~50% with high manual agreement.
Why the study?
To compare manual and semi-automatic measurements for pre-TAVI aortic annulus assessment among operators with different experience levels.
Does semi-automatic CT analysis software improve the reproducibility and speed of pre-TAVI aortic annulus sizing compared to manual measurements?
Observational (n=80)
Readers were blinded to each other's results and to the original clinical measurements
No
Does semi-automatic CT analysis software improve the reproducibility and speed of pre-TAVI aortic annulus sizing compared to manual measurements?
Effect estimate: ICC 0.81-0.98
Semi-automated CT sizing software provides highly reproducible pre-TAVI measurements while cutting analysis time, making it reliable even for less experienced operators.
May expedite pre-TAVI CT analysis across operator experience; leaves open effects on prosthesis selection accuracy and outcomes.
OBJECTIVES: Aim of the study is to compare manual and semi-automatic measurements for aortic annulus assessment among different operators. METHODS: Eighty patients who underwent TAVI were retrospectively enrolled. The measurements manually performed by an experienced reader for aortic annulus (minimum and maximum diameters, perimeter, area), annulus-to-coronary ostia distance and time needed for the whole evaluation, were collected. The same operator (observer 1) and two less experienced readers (observer 2 and 3, with >5 years and 1 year of experience, respectively) assessed the same measurements using a semi-automatic software. Differences between manual and semi-automatic measurements, reading time and suggested valves size derived by CT were compared. RESULTS: Very good correlations were found between manual and software-aided measurements for aortic annulus area and perimeter in comparison with standard measurements for the three readers (ICC range 0.81-0.98). Good correlations were found for the distance with coronary ostia(0.75-0.79). The same area-derived prosthesis size for manual and semi-automatic measurements was selected in 96% of cases for observer 1; very good correlations were also found for observer 2 and 3 (ICC = 0.89 and 0.88, respectively). Using semi-automatic measurements, the mean time needed for CT images was significantly lower for observers 1 and 2 (1.50 and 1.72versus 3.14 min), respectively. CONCLUSIONS: Pre-TAVI CT using semi-automatic software allows accurate and reproducible measurements, reducing reconstruction time up to 50% and is reliable even for operators with different experience. ADVANCES IN KNOWLEDGE: The use of semi-automatic dedicated software for CT in TAVI planning is reliable even for operators without long time experience and allows accurate and reproducible measurements improving pre-TAVI workflow.
No takes yet. Share an insight, caveat, or question.
Annoni et al. (2023) conducted an observational in Severe aortic stenosis (n=80). Semi-automatic CT measurement software (TAVI Analysis) vs. Standard manual CT measurement by an experienced reader was evaluated on Intraclass correlation between manual and semi-automatic measurements for aortic annulus area and perimeter (ICC 0.81-0.98). Semi-automatic CT software provided highly correlated aortic annulus measurements compared to manual assessment (ICC 0.81-0.98) and reduced image analysis time by up to 50% across operators.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: