Key result
Semi-automatic software cuts pre-TAVI aortic root measurement time ~48% vs manual assessment with excellent agreement.
Why the study?
Does semi-automatic software measurement provide comparable results and reduce reading time compared to manual measurement in TAVI candidates undergoing pre-procedural CTA?
Observational (n=120)
Blinded to previous measurements
No
Does semi-automatic software measurement provide comparable results and reduce reading time compared to manual measurement in TAVI candidates undergoing pre-procedural CTA?
Answers are grounded in this paper and cite their sources.
Semi-automatic software for pre-TAVI CTA evaluation significantly reduces reading time while maintaining excellent agreement with manual measurements for prosthesis sizing.
BACKGROUND: Pre-procedural TAVI planning requires highly sophisticated and time-consuming manual measurements performed by experienced readers. Semi-automatic software may assist with partial automation of assessment of multiple parameters. The aim of this study was to evaluate differences between manual and semi-automatic measurements in terms of agreement and time. METHODS: One hundred and twenty TAVI candidates referred for the retrospectively ECG-gated CTA (2nd and 3rd generation dual source CT) were evaluated. Fully manual and semi-automatic measurements of fourteen aortic root parameters were assessed in the 20% phase of the R-R interval. Reading time was compared using paired samples t-test. Inter-software agreement was calculated using the Intraclass correlation coefficient (ICC) in a 2-way mixed effects model. Differences between manual and semi-automatic measurements were evaluated using Bland-Altman analysis. RESULTS: The time needed for evaluation using semi-automatic assessment (3 min 24 s ± 1 min 7 s) was significantly lower (p<0.001) compared to a fully manual approach (6 min 31 sec ± 1 min 1 sec). Excellent inter-software agreement was found (ICC = 0.93 ± 0.0; range:0.90-0.95). The same prosthesis size from manual and semi-automatic measurements was selected in 92% of cases, when sizing was based on annular area. Prosthesis sizing based on annular short diameter and perimeter agreed in 99% and 96% cases, respectively. CONCLUSION: Use of semi-automatic software in pre-TAVI evaluation results in comparable results in respect of measurements and selected valve prosthesis size, while necessary reading time is significantly lower.
No takes yet. Share an insight, caveat, or question.
Horehledova et al. (2018) conducted an observational in Severe aortic valve stenosis (n=120). Semi-automatic CT measurement software vs. Manual CT measurement was evaluated on Measurement time (seconds) (p=<0.001). Semi-automatic software significantly reduced the measurement time for pre-TAVI aortic root evaluation compared to manual assessment (204 vs 391 seconds, p<0.001) while maintaining excellent agreement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: